Site Requirements - Bunn BUNNESPRESS ES2C Operating & Service Manual

Espresso brewer
Table of Contents

Advertisement

BUNN Espress
PHYSICAL
The brewer is for indoor use only on a sturdy counter. It is 26
(49 cm) deep. The brewer weighs approximately 142 pounds (64.5 kg) when the water tank is filled.
PLUMBING
The brewer must be connected to a cold water source with operating pressure between 20 and 90 psi (1.5-
6.5 bar) from a
1
" or larger supply line. Install a valve in the water line before the brewer. Install a regulator
2
before the brewer when the pressure is greater than 100 psi (7 bar) to reduce it to 45-60 psi ( 3-4 bar). The
enclosed water strainer and either of the two enclosed water inlet hose assemblies must be installed before
the brewer.
NOTE-Only softened or demineralized water should ever be used in this espresso brewer to reduce the service
problems caused by naturally occuring elements in your local water supply. A polyphosphate feeder is not
recommended because it does not remove minerals.
NOTE-Bunn-O-Matic recommends
Bunn-O-Matic does not recommentd the use of a saddle valve to install the brewer. The size and shape of the
hole made in the supply line by this type of device may restrict water flow.
ELECTRICAL
The brewer is equipped with an attached cordset and requires a 2-wire, grounded mating receptacle rated
208-240 volts ac, 20 amp, single phase, 60 Hz. An electrician must properly install a NEMA L6-20R connector
to the appropriate electrical service on an individual branch circuit to install this brewer.
CAUTION-The brewer must be properly grounded. A plumbing line will not provide an adequate ground.

SITE REQUIREMENTS

®
3
" copper tubing for no more than 25 feet from the
8
1
" (67 cm) wide,16" (40.5 cm) tall, and 19
2
4
ES•2C
1
"
2
1
" water supply line.
2

Hide quick links: