INSTALLATION INSTRUCTIONS

FLAMMABLE MATERIAL WARNING
Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotech-
nics.
ELECTRICAL CONNECTIONS
A qualified electrician should be used for all electrical connections and/or installations.
DO NOT PERFORM THE INSTALLATION YOURSELF IF YOU ARE NOT QUALIFIED
TO DO SO!
WHEN RUNNING ON 110V POWER, THE UNITS MAY NOT BE LINKED TOGETHER VIA THE
POWER INPUT/OUTPUT TERMINALS! EACH UNIT MUST BE INDEPENDENTLY CONNECTED
TO A POWER SOURCE!
When running on 240V power, however, up to 4 units may be linked together via the power
input/output terminals. Once this values has been reached, a new power outlet must be used
to accommodate additional units. All linked units MUST be of the same make and model type.
DO NOT MIX UNITS!
Fixture MUST be installed following all local, national, and country commercial electrical and con-
struction codes and regulations.
Before rigging/mounting a single fixture or multiple fixtures to any metal truss/structure or placing
the fixture(s) on any surface, a professional equipment installer MUST be consulted to determine if
the metal truss/structure or surface is properly certified to safely hold the combined weight of the
fixture(s), clamps, cables, and accessories.
Maximum fixture ambient operating temperature is 113°F (45°C). Do not operate this fixture when
ambient temperature exceeds this rating.
Fixture(s) should be installed in areas outside walking paths, seating areas, or away from areas
where unauthorized personnel might reach the fixture by hand.
NEVER stand directly below the fixture(s) when rigging, removing, or servicing.
Overhead fixture installation must always be secured with a secondary safety attachment, such as
an appropriately rated safety cable.
Allow approximately 15 minutes for the fixture to cool down before serving.