�6 | BEA ��� � BEA ��� E��� | �peration
5.

Operation

5.�
Switching on�off BEA
Switch on or off with the central mains switch on the
back of the device (see Fig. 2; Item 5).
i
Before switching off the device, you must shut down
the PC using the Windows operating system. Before
switching the device back on again, the PC should
have been switched off for at least 1 minute.
i
When operating the BEA, faults can occur, if a PC or
other components (e.g. mouse, connecting cables)
are used, which have not been supplied by Bosch.
5.2
�peration
The program operation of the "emissions system analy-
sis" can be found in the program description contained
in the supplementary equipment set.
5.�

Software update

The software update of the "emissions system analysis"
can be found in the program description contained in
the supplementary equipment set.
5.�

Notes on faults

Notes on faults in the ESA software can be found in the
program description.
|
1 689 989 034
2008-08-11
6.
Maintenance
6.�

Cleaning

Only clean the trolley, housing and LCD display with soft
cloths and neutral cleansing agents. Do not use any abrasive
cleansing agents or rough workshop cleaning cloths.
6.2

Calibration

When used in areas subject to calibration, it is essential
that calibration is carried out regularly. Take note of
country-specific regulations for this.
6.�

Maintenance and maintenance intervals

i
Routine maintenance maintains the readiness to
operate.
The measurement equipment must be maintained un-
der the conditions stated in the operating instructions
within the periods specified therein. Maintenance can
be carried out by a maintenance service company, or by
competent personnel of the owner of the measurement
equipment; it must be proven and made clear on the
measurement device.
Devices which must be opened (repairs), must subse-
quently be re-calibrated. Device repairs (open device,
adjust, repair, etc.) may only be carried out by the au-
thorized customer service.
Information on maintenance is to be found in the docu-
ment 1 689 979 832 (BEA 050) included in the delivery
specification.
6.�

Spare parts and parts subject to wear

Description
TFT monitor
PC
Mains connection cable
<)
USB mouse
PDR 371
BEA 050
RTM 430
USB connection cable (1 m) to re-
mote control receiver or printer
Remote control
Batteries (4 units)
<)
Part subject to wear
<)
�rder Number
1 687 023 482
1 687 023 480
1 684 461 106
1 687 022 915
1 687 023 435
1 687 022 934
1 687 022 599
1 684 465 491
1 687 246 019
0 092 444 003
Robert Bosch GmbH

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Bea 840 euro

Table of Contents