Terminal Strip For Measuring Unit; Bea 050; Rtm 430; Setting Up - Bosch BEA 810 Product Description

Bosch-emissions-analysis
Hide thumbs Also See for BEA 810:
Table of Contents

Advertisement

Available languages

Available languages

�.5.�

Terminal strip for measuring unit

- 1 C O M
1 5 +
1
2
4
5
3
Fig. 3:
Terminal strip (from below)
1 Temperature sensor
2 Connecting cable B+/B–
3 Connecting cable terminal 1 / Kl. 15 / EST / TN/TD
4 Trigger clamp or
Adapter cable 1 684 465 513 for clip-on sensor
5 RS 232 serial interface (without function)
6 USB connection for PC data connection
7 Measuring unit power supply (power pack)
8 Multi measuring cable CH1 or
9 Stroboscope
10 No function (for future extension)
When measuring speed using the clip-on sensor, the adapter
1)
cable 1 684 465 513 must always be connected between the
FSA 740's plug socket and the connecting cables for the clip-on
sensor.
Voltages of no more than 2�� V may be
measured at the multi measuring cables
CH�. Never apply higher voltages.
�.5.�
BEA �5�
The basic description of the Bosch emissions analysis
module BEA 050, such as design, operating instruc-
tions, maintenance and technical data, can be found in
the operating instructions 1 689 979 832.
�.5.5
�TM ���
The basic description of the Opacimeter module
RTM 430, such as design, operating instructions, main-
tenance and technical data, can be found in the opera-
ting instructions 1 689 979 651.
Robert Bosch GmbH
X
C H 1
U S B
1 5 V D C
45977591-Ko
6
7 8
9
10
1)
Initial start-up | BEA ��� � BEA ��� E��� | �5
BEA ��� � BEA ��� E��� | �5
4.
Initial start-up
�.�

Setting up

1.
Remove packaging and transport protection for all
the supplied parts
2.
Place printer in the trolley (Fig. 1; Item 8) (see installa-
tion instructions 1 689 978 489).
Plug mains connection cable and the USB connec-
3.
tion cable into the printer. Both cables are provided
ready for connection in the trolley.
i
The printer cartridges can only be inserted
when the printer is switched on (see installation
instructions 1 689 978 489).
�.2

Before turning on for the first time

The voltage supply is provided by the lighting mains.
BEA is set ex-factory to 100 V ‒ 230 V, 50/60 Hz. Note
the appropriate details on the sticker on the side of the
BEA device.
BEA 050 is set ex-factory to 230 V. The transformer
mains voltage may only be set by the authorized custo-
mer service. For this, please note the instructions in the
documentation to BEA 050.
!
Before starting up, make sure that the voltage of the
lighting mains matches the voltage set on the BEA. If
the BEA is operated outdoors, we recommend using
a voltage source, which is fused by means of an FI
circuit breaker.
�.�

Language selection by Windows

After turning on for the first time, use the menu to se-
lect the language of the Windows operating system.
It is not possible to subsequently change the language.
However, should this be necessary, please contact your
Bosch authorized dealer.
�.�

Software installation

The software installation of the "emissions system
analysis" can be found in the program description
contained in the delivery specification.
| �5
en
|
1 689 989 034
2008-08-11

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Bea 840 euro

Table of Contents