Cable management

Cabling guidelines

Keep cables away from major heat sources like the heatsink assembly.
Do not jam cables on top of expansion cards or memory modules. Printed circuit cards are not
designed to withstand excessive pressure.
Keep cables clear of sliding or moveable parts to prevent cutting or crimping.
Do not sharply bend any cable. A sharp bend can break the internal wires.
Never bend a SATA/SAS data cable tighter than a 30 mm (1.18 in) radius.
Never crease a SATA/SAS data cable.
Do not rely on components like the drive cage, power supply, or computer cover to push cables
down into the chassis.
Use supplied cable management straps to secure cables.
NOTE:
Always follow good cable management practices when working inside the computer.
To remove power supply power cables and RPS from system board connectors respectively use the
following steps:
Squeeze on the top of the retaining latch attached to the cable end of the connector.
1.
Grasp the cable end of the connector and pull it straight up.
2.
CAUTION:
When removing cables, always pull the connector - NEVER pull on the cable. Pulling the
cable could cause cable damage and result in power supply failure.
Figure 3-5
Unplugging power cables from the system board
All manuals and user guides at all-guides.com
Removal and replacement procedures 31