Specifications - CDP UPO11-1AX User Manual

Table of Contents

Advertisement

6. Specifications

6. Specifications
MODEL
CAPACITY*
INPUT
Low Line Transfer
Low Line
Voltage
Comeback
Range
High Line
Transfer
High Line
Comeback
Frequency Range
Phase
Power Factor
OUTPUT
Output voltage
AC Voltage Regulation
Frequency Range
(Synchronized Range)
Overload
Frequency Range (Batt.
Mode)
Current Crest Ratio
Harmonic Distortion
AC Mode to Batt.
Mode
Transfer
Time
Inverter to
Bypass
Waveform (Batt. Mode)
EFFICIENCY
AC Mode
Battery Mode
BATTERY
Battery Type
Numbers
Standard
Recharge Time
Model
Charging Current
Charging Voltage
Battery Type &
Numbers
Long-run
Model
Charging Current
Charging Voltage
PHYSICAL
Dimension, D X W
Type
X H (mm)
tower
Net Weight (kgs)
ENVIRONMENT
Operation Humidity
Noise Level
MANAGEMENT
Smart RS-232 or USB
Optional SNMP
* Derate capacity to 60% of capacity in Frequency converter mode and to 80% when the output voltage is adjusted to
100Vac, 200Vac or 208Vac.
** Product specifications are subject to change without further notice.
UPO11-1/1.5/2/3 AX Online UPS
UPO11-1AX
UPO11-1.5AX
1000VA/900W
1500VA/1350W
80Vac/70Vac/60Vac/55Vca ± 5% or 160Vac/140Vac/120Vac/110Vac ±5%
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)
100/110/115/120Vac or 200/208/220/230/240Vac
100%- 110 Alarm; 110/130 Battery mode the UPS shuts down in 30 seconds /
normal mode the UPS transfers to bypass mode when the utility is normal;
>130% battery mode the UPS shuts down immediately / normal mode de UPS transfers
2 % THD (Linear Load) ; 4 % THD (Non-linear Load)
90%
89%
12V/7AH
12V/9AH
3
3
4 hours recover to 90% capacity (Typical)
41.0 VDC ± 1%
Depending on the capacity of external batteries
1.0 A/2.0 A/4.0A/6.0 A /8.0 A(max.) (Selectable via LCD setting)
41.0 VDC ± 1%
397 X 145 X 220
13
13.8
20-90 % RH @ 0- 40°C (non-condensing)
Supports Windows® 98/2000/2003/XP/Vista/2008/7, Linux and MAC
Power management from SNMP manager and web browser
UPO11-2AX
2000VA/1800W
84Vac ± 5% or 168 Vac ± 5%
150 Vac ± 5 % or 300 Vac ± 5 %
145 Vac ± 5 % or 290 Vac ± 5 %
40Hz ~ 70 Hz
Single phase with ground
0.99 @ full load
± 1% (Batt. Mode)
47 ~ 53 Hz or 57 ~ 63 Hz
to bypass when the utility is normal
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
3:1
Zero
4 ms (typical)
Pure Sinewave
91%
89%
12V/7AH
6
1.0 A(max.)
82.1 VDC ±1%
26
Less than 50dBA @ 1 Meter
User Manual
UPO11-3AX
3000VA / 2700W
91%
90%
12V/9AH
6
82.1 VDC ±1%
82.1 VDC ±1% 109.6VDC ± 1%
421 X 190 X 318
28
23