Doyon DP9 User Manual

Proofer
Hide thumbs Also See for DP9:

Advertisement

Quick Links

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
SECTION « A » DESCRIPTION
Installation and maintenance manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distances to respect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation of unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance and cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
For more information, please call our office: . . . . . . . . . . . . . . . . . . . . . . .
SECTION « B » DIMENSIONS
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION « E » COMPONENT PARTS
Component parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION « G » ELECTRIC SHEMATIC
DP9 - 120V/1PH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DP9 - 230V/1PH/50 Hz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DP9_A.DOC
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
CAREFULLY FOLLOW THESE INSTRUCTIONS
TABLE OF CONTENTS
DP9
DANGER
REV.09/01/06
PAGE
A1
A2
A2
A3
A4
A4
A5
A6
A7
A8
B1
E1
G1
G2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DP9 and is the answer not in the manual?

Questions and answers

Summary of Contents for Doyon DP9

  • Page 1 DP9 - 230V/1PH/50 Hz ........
  • Page 2: Installation And Maintenance Manual

    DOYON is not responsible for damages to the property or the equipment caused by personnel who is not certified by known organizations. The customer is responsible for finding qualified technicians in electricity and plumbing for the installation of the oven.
  • Page 3 C O N S T R U C T I O N You just bought the most advanced proofer in the world, the "DOYON" technology at its best. This proofer is manufactured using the highest quality components and material. The DOYON equipments are designed with parts that are easy to find.
  • Page 4: For Your Safety

    The proofer must be connected to the utility and electrically grounded in conformity to the effective local regulations. If these are not established, the oven must be connected according to the Canadian Electrical Code (CSA-C22.1- XX) or National Electrical Code (NFPA 70-XX). Refer to last...
  • Page 5: Distances To Respect

    Connect the steam system (1/4 NPT) to the cold water distribution network. We highly recommend a water softener to eliminate minerals in the water. We suggest to use CUNO # CFS6135 (Doyon part number PLF240). Do not adjust the needle valves it has in been done at the factory...
  • Page 6: Operation

    1. Switch "ON". 2. Set the thermostat control at 100 3. Set the humidity control at 3. If there is too much fog and water drips from the glass doors, adjust humidity control to a lower number. 4. When the temperature is stabilized, put the products in the proofer (Leave them inside until they are ready to bake.) 5.
  • Page 7: Troubleshooting

    BEFORE CALLING FOR SERVICE ANSWERS TO MOST FREQUENT QUESTIONS Always cut off the main power before replacing any parts. Take care of water piping and electric cable. Control parts on the front: Control panel, proofer unit and refrigeration units. Questions The unit does not turn on when installed.
  • Page 8: Maintenance And Cleaning

    Blast : Concentrated for industrial use KEM Mfg Canada Part number : NEB201 Warning: Never use cleaners such as Easy- Off or equivalents in the oven. We recommend and sell: Stapol: Stainless steel polish KEM Mfg Canada Part number : NES201...
  • Page 9: For More Information, Please Contact Our Office

    FOR MORE INFORMATION, PLEASE CONTACT OUR OFFICE : DOYON EQUIPMENT INC. 1255, rue Principale Linière, Qc, Canada G0M 1J0 Tel. : 1 (418) 685-3431 Canada : 1 (800) 463-1636 U.S. : 1 (800) 463-4273 FAX : 1 (418) 685-3948 Internet: www.doyon.qc.ca...
  • Page 10: Dimensions

    SECTION DIMENSIONS...
  • Page 11 35 1/2 40 1/2...
  • Page 12 31 1/4 40 1/2...
  • Page 13 ENTRÉE ÉLECTRIQUE ELECTRICAL INLET 35 1/2 ENTRÉE D’EAU Ø1/4" WATER INLET Ø1/4"...
  • Page 14: Component Parts

    SECTION COMPONENT PARTS...
  • Page 16 Item Part Number QUP320 P1431E QUP465 ELT627 ELT628 ELT620 ELL650 ELI220 ELI240 ELI550 ELI555 ELI556 ELB096 ELB097 PAR100 QUA200 Model : DP-9 Description DOOR HINGE PROOFER DOOR 14 1/4" X 31 1/2" DOOR HANDLE STAINLESS TUBING THERMOSTAT 110F THERMOSTAT KNOB 110F THERMOSTAT BEZEL PILOT LIGHT INFINITY SWITCH 120V (HUMIDITY CONT.)
  • Page 18 Item Part Number ELE130 ELM730 ELD050 ELC860 ELC615 ELC617 ELB071 ELL050 ELS880 PLF100 ELV590 QUF350 ELE165 ELT712 Model : DP-9 Description COIL ELEMENT 120V 1500W PROOFER FAN BLOWER INCANDESCENT LIGHT SOCKET CONTACTOR 2P 30A 110V RELAY 10A 2P COIL 110V BASE TERMINAL BLOCK 2P 175A GROUND LUG...
  • Page 19: Electric Schematic

    SECTION ELECTRIC SCHEMATIC...
  • Page 22: Limited Warranty

    LIMITED WARRANTY (Continental United States Of America And Canada Only) Doyon Equipment Inc. guarantees to the original purchaser only that its product are free of defects in material and workmanship, under normal use. This warranty does not cover any light bulbs, thermostat calibration or defects due to or resulting...

Table of Contents