Doyon DRIP1 User Manual

Doyon DRIP1 User Manual

Digital control proofer

Advertisement

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
SECTION « A » DESCRIPTION
Installation and maintenance manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distances to respect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operation of unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maintenance and cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A7
For more information, please contact our office: . . . . . . . . . . . . . . . . . . . . A9
DRIP1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E236 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E336 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E460 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION « E » COMPONENT PARTS
Front view component parts for all models (except E460) . . . . . . . . . . . .
Front view for E460 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DRIP1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E236. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E336. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E460. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DRIP1, E236, E336, E460
DIGITAL CONTROL
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
CAREFULLY FOLLOW THESE INSTRUCTIONS

TABLE OF CONTENTS

DANGER
PAGE
A1
A4
A5
B1
B3
B6
B9
E1
E3
E5
E7
E9
E11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DRIP1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Doyon DRIP1

  • Page 1: Table Of Contents

    DRIP1 ........
  • Page 2 DRIP1 - 120V/1PH/60HZ ........
  • Page 3: Installation And Maintenance Manual

    Drawings, electrical diagram and replacement part numbers are included in this manual. The electrical diagram is affixed in the control panel located on the top of the proofer. DOYON is not responsible for damages to the property or the equipment caused by personnel who is not certified by known organizations. The customer is responsible for finding qualified technicians in electricity and plumbing for the installation of the oven.
  • Page 4: Construction

    C O N S T R U C T I O N You just bought the most advanced proofer in the world, the "DOYON" technology at its best. This proofer is manufactured using the highest quality components and material. The DOYON equipments are designed with parts that are easy to find.
  • Page 5: Warnings

    The proofer must be connected to the utility and electrically grounded in conformity to the effective local regulations. If these are not established, the oven must be connected according to the Canadian Electrical Code (CSA-C22.1-XX) or National Electrical Code (NFPA 70-XX). Refer...
  • Page 6: Distances To Respect

    Connect the steam system (1/4 NPT) to the water distribution network. We highly recommend to use a water softener to eliminate minerals in the water. We suggest you to use CUNO # CFS6135 (Doyon part number PLF240). Do not adjust the needle valves, it has been done at the factory.
  • Page 7: Operation Of The Digital Control

    OPERATION OF THE DIGITAL CONTROL 1. Turn the main switch to " 1 ". 2. The light inside the proofer will turn ON and the digital control will indicate a code. Then, "PREH" will flash. 3. "PREH" will be displayed on the control until it reaches the set temperature. To check and modify: Temperature settings : Press and hold down for 2 seconds the temperature key Humidity settings : Press and hold down for 2 seconds the humidity key and...
  • Page 8: Troubleshooting

    BEFORE CALLING FOR SERVICE, ANSWERS TO THE MOST FREQUENT QUESTIONS Always cut off the main power before replacing any parts. Take care of water piping and electric cable. Control parts on the front. Control panel, proofer unit and refrigeration units. Questions The unit does not turn on when installed.
  • Page 9: Maintenance And Cleaning

    MAINTENANCE AND CLEANING Step by step Clean the inside of the unit with water and soap. Clean the unit exterior with a stainless steel polish. Clean the windows with products like Brasso or equivalents. They are copper cleaners but good for this use. Recommendations We recommend and sell: Dirt Buster III : Action foam cleaner...
  • Page 11: For More Information, Please Contact Our Office

    FOR MORE INFORMATION, PLEASE CONTACT OUR OFFICE: DOYON EQUIPMENT INC. 1255, rue Principale Linière, Qc, Canada G0M 1J0 Tel. : 1 (418) 685-3431 Canada : 1 (800) 463-1636 U.S. : 1 (800) 463-4273 FAX : 1 (418) 685-3948 Internet: http://www.doyon.qc.ca E-Mail : doyon@doyon.qc.ca...
  • Page 12: Section « B » Dimensions

    SECTION DIMENSIONS...
  • Page 13: Drip1

    DRIP1 DRIP−1F...
  • Page 15 E2−36−F E236...
  • Page 18 E336 E3−36−F...
  • Page 21 E4−60−F E460...
  • Page 23: Component Parts

    SECTION COMPONENT PARTS...
  • Page 25 Item Part Number ELB096 5A BREAKER ELT540 ELECTRONIC RELATIVE HUMIDITY CONTROL ELT542 DECAL FOR ELT540 ELI550 MAIN SWITCH ELI555 CONTACT BLOCK 1NO ELF660 VAPOR TYPE FIXTURE ELA275 BULB 60W 130V ELF650 PLASTIC BULB PROTECTOR QUP520 MAGNETIC HANDLE P2969E PROOFER DOOR 29 x 69 1/4 QUE500 DOOR GASKET(15`) QUP320...
  • Page 27 Item Part Number ELT541 PROBE FOR ELT540 ELB096 5A BREAKER ELT540 ELECTRONIC RELATIVE HUMIDITY CONTROL ELT542 DECAL FOR ELT540 ELI550 MAIN SWITCH ELI555 CONTACT BLOCK 1NO ELF660 VAPOR TYPE FIXTURE ELA275 BULB 60W 130V ELF650 PLASTIC BULB PROTECTOR QUP520 MAGNETIC HANDLE P2969E PROOFER DOOR 29 x 69 1/4 QUE500...
  • Page 29 ELC617 BASE ELB081 20A DOUBLE BREAKER ELB082 30A DOUBLE BREAKER ELC908 HEATING CONTACTOR ELM735 SOLID STATE TIMER ICM ELC640 CONTROL RELAY BASE ELC630 CONTROL RELAY 12A COIL 120V ELT541 PROBE FOR ELT540 Model : DRIP1 Description Quantity View : TOP...
  • Page 31 Item Part Number ELM731 MOTOR BLOWER 115 CFM ELE168 IMMERSION ELEMENT 240V 3000W ELE169 IMMERSION ELEMENT 208V 3000W ELE134 COIL ELEMENT 240V 4000W ELE133 COIL ELEMENT 208V 4000W QUF350 ELECTRIC FLOAT ELS880 SOLENOID VALVE 110/120V 50/60Hz PLF100 WATER FILTER ELV590 NEEDLE VALVE ELL050 GROUND LUG...
  • Page 33 Item Part Number ELE116 COIL ELEMENT 240V 2000W ELE106 COIL ELEMENT 208V 2000W ELM731 MOTOR BLOWER 115 CFM ELE168 IMMERSION ELEMENT 240V 3000W ELE169 IMMERSION ELEMENT 208V 3000W QUF350 ELECTRIC FLOAT ELS880 SOLENOID VALVE 110/120V 50/60Hz PLF100 WATER FILTER ELV590 NEEDLE VALVE ELL050 GROUND LUG...
  • Page 35 Item Part Number ELM763 MOTOR BLOWER 120V 265 CFM ELE168 IMMERSION ELEMENT 240V 3000W ELE169 IMMERSION ELEMENT 208V 3000W ELE132 COIL ELEMENT 240V 1500W ELE131 COIL ELEMENT 208V 1500W ELE134 COIL ELEMENT 240V 4000W ELE133 COIL ELEMENT 208V 4000W QUF350 ELECTRIC FLOAT ELS880 SOLENOID VALVE 110/120V 50/60Hz...
  • Page 36: Electric Schematics

    SECTION ELECTRIC SCHEMATICS...
  • Page 37 TOTAL POWER: 4.7 Kw 60 Hz TIMER 5 SEC. AC−IN 1 2 3 4 5 BACK VIEW DC−IN/OUT AC−OUT 1 2 3 4 SERIAL LINK AN−1 PROBE DRIP1 120V 1 PHASE 60 Hz 22/08/05 M. FAUCHER STANDARD DRIP1 NONE LOAD 1 / 1...
  • Page 38 5 SEC. PROOFER VALVE AC−IN 1 2 3 4 5 BACK VIEW DC−IN/OUT AC−OUT 1 2 3 4 SERIAL LINK AN−2 DRIP1 1 PHASE 60 Hz 22/08/05 M. FAUCHER 60 Hz STANDARD NONE LOAD AN−1 PROBE 1 / 1 DRIP1_0...
  • Page 41 5 A. ON/OFF 30 A 20 A BULB 4.0 KW HEAT 3.0 KW HUMIDITY 120 / 208 1.6A 120 / 240 1.6A TOTAL POWER: 7.2 Kw LIQUID TIMER LEVEL 5 SEC. PROOFER VALVE AC−IN 1 2 3 4 5 BACK VIEW DC−IN/OUT AC−OUT 1 2 3 4...
  • Page 42 FOR SUPPLY SYSTEMS CONSISTING OF A DELTA SECONDARY TRANSFORMER, MAKE SURE THAT THE PHASE FEEDER WITH THE HIGHEST VOLTAGE (HIGH LEG) IS CONNECTED TO L3 IN THE SUPPLY BOX OF THIS OVEN (120 / 240V. 3 PH. SYSTEMS). ON/OFF PROOFER BULB VALVE 4.0 KW...
  • Page 45 ON/OFF 5 A. HIGH T° LIMIT 300°F 30 A 20 A LIQUID LEVEL PROOFER BULB VALVE BACK VIEW 2 x 2.0 KW AN−2 HEAT 3.0 KW HUMIDITY 120 / 208 2.5A 34.6A 32.6A 120 / 240 2.5A 31.0A 29.0A TOTAL POWER: 7.5 Kw 60 Hz TIMER 5 SEC.
  • Page 47 ON/OFF 5 A. HIGH LIMIT 300°F 40 A 20 A BULB PROOFER VALVE 1.5 KW 4.0 KW HEAT HEAT 3.0 KW HUMIDITY 120 / 208 2.5A 41.0A 40.0A 120 / 240 2.5A 36.0A 35.0A TOTAL POWER: 8.5 Kw LIQUID TIMER LEVEL 5 SEC.
  • Page 49: Limited Warranty

    LIMITED WARRANTY (Continental United States Of America And Canada Only) Doyon Equipment Inc. guarantees to the original purchaser only that its product are free of defects in material and workmanship, under normal use. This warranty does not cover any light bulbs, thermostat calibration or defects due to or resulting...

This manual is also suitable for:

E336E460E236r

Table of Contents