To Wire a Single Speed, Single Voltage Motor
Remove the motor end cover.
There are two terminals labeled L1 and L2. Attach the
power leads to these terminals. Either wire may attach to
either terminal.
To Wire a Dual-Voltage Motor
Dual voltage motors have a plug to change from 230 volts
(factory setting) to 115 volts.
Figure 5A -Voltage Change
Plug Set for 230 Volts
Motor
HP
3/4
1
1-1/2
3/4
1
1-1/2
2
3
3/4
1
1-1/2
2
3
3/4
1
1-1/2
2
3
* Time delay fuses are recommended instead of standard fuses in any motor circuit.
Figure 5B Voltage Change
Plug Set for 115 Volts
TABLE I - RECOMMENDED FUSING AND WIRING DATA
Branch Fuse
Max Load
Rating Amps*
Amps
20
12.2
20
15.4
30
19.4
15
6.1
15
7.7
15
9.7
20
10.5
20
13.9
15
3.6
15
4.0
15
5.15
15
6.6
15
8.0
15
2.1
15
2.3
15
3.0
15
3.8
15
4.7
1. If you have 230 volts motor supply voltage, confirm
that the plug is set for 230 volts. The arrow on the plug
will point to the 230 volt position. Note that plug only
connects with one prong in this position.
2. If you have 115 volt supply, pull the plug straight up
and place it on the two brass prongs as shown.
NOTE: Arrow is highlighted for clarity.
Serv. to Motor - Dist. Meters
Voltage/
Hz/Phase
0-30 M
31-61 M
115/50/1
3.0
115/50/1
3.0
115/50/1
5.5
230/50/1
2.0
230/50/1
2.0
230/50/1
2.0
230/50/1
2.0
230/50/1
3.0
220/50/3
2.0
220/50/3
2.0
220/50/3
2.0
220/50/3
2.0
220/50/3
2.0
380/50/3
2.0
380/50/3
2.0
380/50/3
2.0
380/50/3
2.0
380/50/3
2.0
6
62-91 M
}
5.5
8.4
Wire
8.4
14.0
Size
mm
8.4
14.0
2.0
2.0
}
2.0
2.0
Wire
Size
2.0
3.0
mm
2.0
3.0
3.0
5.5
2.0
2.0
}
2.0
2.0
Wire
Size
2.0
2.0
mm
2.0
2.0
2.0
2.0
2.0
2.0
}
2.0
2.0
Wire
Size
2.0
2.0
mm
2.0
2.0
2.0
2.0
2
2
2
2