evoheat CS-i Series Installation & Operation Manual

evoheat CS-i Series Installation & Operation Manual

Hide thumbs Also See for CS-i Series:

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CS-i Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for evoheat CS-i Series

  • Page 2: Table Of Contents

    EvoHeat CS-i Commercial Inverter Series Heat Pump Contents 1. Introduction __________________________________________________________________________________ 2 2. Unit Dimensions ______________________________________________________________________________ 3 3. Safety Instructions _____________________________________________________________________________ 4 4. Installation ___________________________________________________________________________________ 5 4.1 System Installation _________________________________________________________________________ 5 4.2 Location Recommendations __________________________________________________________________ 6 4.3 Airflow Clearances __________________________________________________________________________ 6 4.4 Adequate Water Flow _______________________________________________________________________ 7...
  • Page 3: Introduction

    *The data above is based on the EVO heat pump only, it does not include auxiliary devices. Product specification information provided above is correct at the date ofprinting, this data may change without notice. Please speak with an EvoHeat Specialist for the most current product...
  • Page 4: Unit Dimensions

    EvoHeat CS-i Commercial Inverter Series Heat Pump 2. Unit Dimensions Evo CS-i 65 unit:mm Evo CS-i 130 A (L) B (W) C (H) Water inlet/outlet CS-i 65 1750mm 830mm 1750mm Ø50 CS-i 130 2260mm 1160mm 2127mm 100mm flange...
  • Page 5: Safety Instructions

    EvoHeat CS-i Commercial Inverter Series Heat Pump 3. Safety Instructions • Installation, repair or relocations must be done by a fully qualified person and not by the customer. If done incorrectly it may cause fire, electric shock, water leakage and other hazards.
  • Page 6: Installation

    EVOHEAT ACCESSORIES – DO NOT THROW AWAY All EvoHeat units are provided with rubber feet, controller and leads for the controller– do not throw them away as they are required as part of the installation.
  • Page 7: Location Recommendations

    EvoHeat recommend a 1500mm clearance between units. *Fan discharge distance can be reduced by adding a Plenum to alter the air flow direction. Contact EvoHeat or a HVAC specialist for further advice. If you do not have a location with these suggested clearances, please contact our EvoHeat Tech Support Specialist to discuss appropriate installation locations.
  • Page 8: Adequate Water Flow

    It is CRITICAL that there is sufficient water flow to the unit. Incorrect water flow can cause a loss of efficiency and possible damage to the unit. Optimal water flow rates are listed in the EvoHeat manual. It is imperative that water flow is kept as close as possible to these flow rates.
  • Page 9: Electrical Connection

    EvoHeat CS-i Commercial Inverter Series Heat Pump 4.8 Electrical Connection IMPORTANT: Always use a qualified Electrician to perform any electrical work. A licensed electrician must read the information before connecting. Ensure the power cable and circuit breaker are of a suitable size for the heater being installed. Also check that there is adequate voltage and current available at the heater connection to run the unit.
  • Page 10: Operation

    EvoHeat CS-i Commercial Inverter Series Heat Pump 5. Operation Scan the QR Code or head to our YouTube channel for step by step videos. https://www.youtube.com/evoheat 5.1 Main Controller Interface Number Name Button Function ON/OFF Press to turn the unit on or off.
  • Page 11: Clock Settings

    EvoHeat CS-i Commercial Inverter Series Heat Pump 5.2.3 Clock Settings After clicking the Clock button, a menu will appear where you can choose to adjust either Time or Timer settings. Setting the Date & Time Click the value you wish to change to set the time directly. Press confirm to save the settings.
  • Page 12: Fault History

    EvoHeat CS-i Commercial Inverter Series Heat Pump Name Colour Function Timing silent off Used: Red Click to use or unused timing off function Unused: Grey Timing silent on Used: Green Click to use or unused timing silent function Unused: Grey...
  • Page 13: Troubleshooting

    6. Troubleshooting EvoHeat have developed a YouTube Channel where you will find useful videos - from setting up your timers to setting up the EvoHeat app. View it to see resolutions to some of our most asked, yet easily solved questions: https://www.youtube.com/channel/UCfYiOxHuybBuC1NZcqUnrcA...
  • Page 14 If the water has no chlorine then it is condensation and is it normal – see drainage and condensation for more information. If the water has chlorine, it is a water leak and you need to contact EvoHeat tech support on 1300 859 933.
  • Page 15: Error Codes

    EvoHeat CS-i Commercial Inverter Series Heat Pump 6.1 Error Codes Electronic Control Fault Table Fault Protect/fault Reason Elimination methods display Inlet Temp. Sensor Fault The temp. Sensor is broken or short circuit Check or change the temp. Sensor Outlet Temp. Sensor Fault The temp.
  • Page 16 EvoHeat CS-i Commercial Inverter Series Heat Pump Frequency Conversion Board Fault Table Fault Protect/fault Reason Elimination methods display MOP drive alarm Recovery after the 150s Drv1 MOP alarm Frequency conversion board and Check the communication connection Inverter offline main board communication failure...
  • Page 17: Appendix

    EvoHeat CS-i Commercial Inverter Series Heat Pump 7. Appendix 7.1 Parameter List Meaning Default Remarks Refrigeration target temperature set point 27°C Adjustable Heating the target temperature set point 27°C Adjustable Automatic target temperature set point 27°C Adjustable 7.2 Cable Specifications...
  • Page 18: Wiring Diagrams

    EvoHeat CS-i Commercial Inverter Series Heat Pump 7.3 Wiring Diagrams 7.3.1 CS-i 65...
  • Page 19: Cs-I 130

    EvoHeat CS-i Commercial Inverter Series Heat Pump 7.3.2 CS-i 130...
  • Page 20 EvoHeat CS-i Commercial Inverter Series Heat Pump Number Sign Meaning OUT1 Compressor (output 220-230VAC) OUT2 Water pump (output 220-230VAC) OUT3 4-way valve (output 220-230VAC) OUT4 High speed of fan (output 220-230VAC) OUT5 Low speed of fan (output 220-230VAC) AC-L Live wire (input 220-230VAC)
  • Page 21: Maintenance

    DO I NEED TO GET MY UNIT SERVICED? It is highly recommended that you get your EvoHeat unit serviced at least once a year by your local certified air conditioning or refrigeration technician. If your unit is located in a coastal area, more frequent maintenance may be necessary. During the service, they will check the operational pressures of the refrigeration system and give the unit and fins a good clean to ensure maximum performance.
  • Page 22: Warranty

    Warranty Registration EvoHeat highly recommend customers to complete their warranty details online to ensure efficient warranty claim processing. To register your warranty, scan our QR Code or head to our website and fill in the Warranty Registration Form: https://evoheat.com.au/warranty-registration/...