Bedknife
Removing the Bedknife
Installing the Bedknife
DPA Cutting Units: Service and Repairs
g227001
1.
Bedknife screw (13 used)
2.
Bedknife
1.
Remove the bedbar from the cutting unit; refer to
(page
7–5).
2.
Remove screws from bedbar using a socket wrench and bedknife screw tool;
refer to
Special Tools (page
from the bedbar.
3. Refer to
Grinding the Bedknife (page 7–12)
1.
Use a scraper to remove all rust, scale and corrosion from the bedbar
surface under the bedknife. Lightly oil the bedbar surface before installing
the bedknife.
2.
Make sure that screw threads in bedbar (5/16-18UNC-2A) are clean.
g226894
Figure 101
3.
Bedbar
2–13). Discard the screws. Remove bedknife
Figure 102
Page 7–10
Removing the Bedbar
for additional information.
Greensmaster
20248SL Rev A
®
eFlex 1021