CARBON WATER FILTER SYSTEM TANK INSTALLATION
1. Level the Carbon Water Filter System Tank.
Note: See "Troubleshooting" section on tips for leveling the tank.
Notice
If the tank is not level, lift the tank straight up six (6) inches and tap it on the ground until the tank stands vertically.
The bottom of the tank is round and the boot allows the tank to stand upright.
Incoming
Water
Supply
Top View
2. Determine the size and material of your incoming water supply line from the Carbon Water Filter and choose the appropriate
fittings required to connect it to the filter head.
Caution
Do not over-tighten any of the fittings during installation.
Note: Visit pentair.com/homewater to view our full line of installation kits.
3. Install the fittings into the INLET and OUTLET sides of the filter.
4. Connect the incoming water supply from the sediment filter to the fitting on the INLET side of the filter.
5. Connect the outgoing water supply to the OUTLET side of the filter