Cadel NICE Installation, Use And Maintenance Handbook page 84

Table of Contents

Advertisement

Available languages

Available languages

PROBLEM
Weak orange
coloured flame,
pellets not burning
properly and glass
blackened.
Heat exchanger fan
keeps turning even
when stove has
cooled.
Ash around stove
Stove goes off
Alarm on display
"AlAr no rEtE"
Stove working,
display shows "RiS"
Stove goes off
Alarm on display
"AlAr Sond"
Alarm on display
"AlAr Fan Fail"
Pag. 84
CAUSE
Not enough combustion air
Exhaust obstructed
Stove clogged
Fumes extractor broken down
Faulty fumes temperature probe
Faulty electronic circuit board
Door gasket faulty or torn
Fumes channel pipes not
hermetically sealed
Plug accidentally disconnected
Temporary power failure
Faulty electronic circuit board
Ambient temperature reached
Fumes
outlet
temperature
reached
Fumes temperature probe
disconnected
Faulty fumes temperature probe
Fumes extractor broken
Check the following items: any obstructions to air
entry at back of stove; remove or adjust PVC cap
(if applicable) regulating the air inlet pipe; ash
clogged holes in the burn pot grid and/or seat;
clean fan blades and worm screw (see
pages 79 and
following).
The outlet chimney is partly or completely
clogged (check with an expert what's necessary
from the stove outlet up to the chimney). Clean
immediately.
Clean inside of stove (see
and
following).
Pellets burn also due to the draught in the flue
without the aid of an extraction device. Replace
fumes extractor immediately: stoves operating
without a fumes extractor may be a health
hazard. Call an expert.
Replace fumes probe
Call an expert.
Replace electronic circuit board
Call an expert.
Replace gaskets
Seal
connections
temperature silicone) and/or replace pipes with
others to current standards. Fumes channels not
hermetically sealed may be a health hazard. Call
an expert.
Check that plug is plugged into mains.
Check and re-start stove.
Replace electronic circuit board
Call an expert.
Stove works on minimum, no problem.
limit
Stove works on minimum, no problem.
Have an expert check that probe is
connected to circuit board and/or inserted and
secured in its seat on the extractor.
Have an expert replace fumes probe.
Fumes extractor working at maximum rpm.
Replace exhaust pipe immediately.
Call an expert.
MIRIAM-NICE-DIANA-PRETTY-MARY
SOLUTION
chapter 7,
chapter 7, pages 79
immediately
(with
high

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

DianaMiriamPrettyMary

Table of Contents