Smoke Control Areas and you can contact them for details of Clean Air Act requirements. The HWAM 2600 stoves detailed below have been recommended as suitable for use in smoke control areas when burning wood logs.
In general Congratulations on your new HWAM woodburning stove. We are pleased that you have chosen a HWAM woodburning stove and confident that it will give you much pleasure. To ensure optimum operation and safety, we recommend that the installation should be carried out by an authorised HWAM retailer or a fitter recommended by the retailer.
Page 10
Distance to combustible materials If HWAM 2610/2620 is placed on a combustible floor, always mount it on a plinth whether or not the floor is covered by a non-combustible material, such as a plate of glass or steel. The plinth is an accessory.
Page 11
The chimney and flue duct must be of flue class T400 and be CE marked. Furthermore, it must have obtained the classification of G in soot fire testing. The required distance to combustible material must be complied with in accordance with the brand label. Ask your HWAM retailer for further information.
Page 12
and down to the bottom plate. Vertical cross-section of the stoves (Drawing B): • The smoke shelf (5): Should rest on the rear plate and on the stand uppermost in the front of the combustion chamber. • The baffle plate (6): Is suspended on two hooks, one in either side uppermost in the combustion cham- ber.
iring manUal wood Your first heating session The lacquer will be fully hardened after the stove has been used, and the door and the ashpan should be opened very carefully as there will otherwise be a risk that the gaskets will stick to the lacquer. In addi- tion the lacquer may initially give off an unpleasant odour, so make sure that the room is well ventilated.
Page 14
Do not place the firewood too close to the door glass. Never pile wood above the air slot in the vermiculite rear plate. Do not regulate the stove again as the HWAM Autopilot™ will do ®...
iring in general Rapid or fierce heat Rapid or fierce heat is obtained by burning many small pieces of wood. Maximum amounts of fuel: The maximum allowed amount of fuel per hour is: Wood: 2.0 kg If these limits are exceeded, the stove will no longer be covered by the factory guarantee, and it may also become damaged due to excessive heat, the glass may turn white, for example..
All service checks must be performed by an authorised fitter. Use only original spare parts Inside cleaning Before chimney sweeping can be performed, the air control knob must be set to its minimum position to prevent soot and ash from entering the HWAM Autopilot™. Unless the safety fittings for transportation ®...
cold or hot. By rising or falling temperatures it must not move at a bound. The damper plates must be dry and clean and slide together unhindered. Control bars and slide gates may have to be smeared with WD40 (never oil). Door/glass A sooty glass door can easily be cleaned with a piece of moist kitchen roll dipped in ash.
The DoP can be downloaded from our website via the following links: www.hwam.com/dop/2610 www.hwam.com/dop/2620 www.hwam.com/dop/2630 www.hwam.com/dop/2640 Page 18 of 20 pages...
Product information on solid fuel local space heaters according to Comission regulation (EU) 2015/1185 HWAM 2610, HWAM 2620, HWAM 2630, HWAM 2640 Model Direct heat output [kW] Indirect heating functionality Indirect heat output [kW] Two ore more manual stages, no temperature control...