en | Connection
2
2.
AUTODOME Programmed N.O.
Circuit
Open
Closed
Configuring a Normally Closed Non-supervised Alarm
1.
Figure 13.5: N.C. Normally Closed Non-supervised Connections
1
2
2.
AUTODOME Programmed N.C.
Circuit
Open
Closed
Alarm Outputs
The camera incorporates two (2) types of alarm outputs: one dry contact relay and three (3)
open collector outputs or transistor outputs.
Configuring a Dry Contact Relay
The dry contact relay acts like an on/off switch. It has a maximum voltage rating of 2 A @
30 DC.
1.
2.
Configuring an Open Collector Output
Outputs 1, 2, and 3 are open collector types. These outputs must be connected to a positive
voltage between 5 and 32 V to complete the circuit, with a maximum voltage rating of 32 VDC
@ 150 ma.
1.
2.
2021-03 | 1.2 |
Alarm Inputs 3 to 7
From Configuration, select Interfaces > Alarm Inputs, select the number of the Alarm
input and finally, select N.O. See the table below for contact and condition details.
Alarm Indication
Normal
Alarm
Connect the alarm to the appropriate input (3 through 7) and ground at the camera.
Dry Contact
Alarm Inputs 3 to 7
From Configuration, select Interfaces > Alarm Inputs, select the number of the Alarm
input and finally, select N.C. See the table below for contact and condition details.
Alarm Indication
Alarm
Normal
Connect the appropriate stripped wire to the camera's COM connector.
Connect the appropriate stripped wire to the N.O. or N.C. connector, depending on your
requirement.
Connect the appropriate stripped wire to the open connector (1, 2, or 3) of the
transistor.
Connect the appropriate stripped wire to the ground (GND) connector.
4
3
4
Installation Manual
AUTODOME IP starlight 7000i
Ground
Dome Connector
Ground