Chenbro RB13804N4WFT User Manual

Rackmount chassis
Table of Contents

Advertisement

Quick Links

RB13804N4WFT
User Manual
Rackmount Chassis
March 2020 Version 1.1
A document provides an overview of product features, functions, architecture, and support specifications.

Advertisement

Table of Contents
loading

Summary of Contents for Chenbro RB13804N4WFT

  • Page 1 RB13804N4WFT User Manual Rackmount Chassis March 2020 Version 1.1 A document provides an overview of product features, functions, architecture, and support specifications.
  • Page 2 No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document. Chenbro disclaims all express and implied warranties, including without limitation, the implied warranties of merchantability, fitness for a particular purpose, and non-infringement, as well as any warranty arising from course of performance, course of dealing, or usage in trade.
  • Page 3: Table Of Contents

    RB13804N4WFT Table of Contents Table of Contents ............................3 List of Figures ..............................4 List of Tables................................6 Product Overview.......................... 7 1-1 System Features Overview ...................... 8 1-2 Front Panel ..........................9 1-3 Back Panel ..........................10 1-4 Front Control Panel ....................... 11 1-5 Chassis Dimensions .......................
  • Page 4: List Of Figures

    RB13804N4WFT List of Figures Figure 1 Overview ............................ 8 Figure 2 Major components overview ...................... 8 Figure 3 Front panel ..........................9 Figure 4 Back panel with redundant PSU ....................10 Figure 5 Front control panel ........................11 Figure 6 Chassis dimensions ........................
  • Page 5 RB13804N4WFT Figure 32 CRPS module removal ......................30 Figure 33 Slide rail installation-1 (84H314610-003) .................. 31 Figure 34 Slide rail installation-2 (84H314610-003) ..................31 Figure 35 Slide rail installation-3 (84H314610-003) ..................32 Figure 36 Slide rail installation-4 (84H314610-003) .................. 32 Figure 37 Drive tray LED identification .....................
  • Page 6 RB13804N4WFT List of Tables Table 1 Chenbro RB13804N4WFT specifications ..................7 Table 2 Front control panel ........................11 Table 3 Slide rail installation ......................... 13 Table 4 System environmental specifications summary ................ 14 Table 5 System packing information ..................... 15 Table 6 Product weight information .....................
  • Page 7: Product Overview

    RB13804N4WFT 1. Product Overview RB13804N4WFT fulfills 1U full featured computing server chassis. It is furnished with powerful computing capability, flexible storage, add-in card, and fan configurations to meet business IT, datacenter, and cloud applications. This chapter provides a high-level overview of the system features and available options. More details for each major sub-system, feature or option are provided in the following chapters.
  • Page 8: System Features Overview

    RB13804N4WFT 1-1 System Features Overview Figure 1 Overview Figure 2 Major components overview A. Front Top Cover D. Rear Top Cover Latch G. Fan Assembly B. Rear Top Cover E. Power Supply Unit C. Label Embossing F. Server Board Product Overview...
  • Page 9: Front Panel

    RB13804N4WFT 1-2 Front Panel Figure 3 Front panel A. Rack Handles C. Info Tag E. Front Control Panel B. Bay Latch D. Storage Drive Bay Product Overview │...
  • Page 10: Back Panel

    RB13804N4WFT 1-3 Back Panel Figure 4 Back panel with redundant PSU A. Redundant Power Supply Unit D. Serial Port A (RJ45) G. Intel I/O Module Bay B. NIC (RJ45) Stacked USB2.0/3.0 Ports C. Video Port (VGA) Remote Management Product Overview...
  • Page 11: Front Control Panel

    RB13804N4WFT 1-4 Front Control Panel Figure 5 Front control panel Table 2 Front control panel Label ICON Indicator, button or connector Power Button LAN1, LAN2 Activity LED Power LED HDD Activity LED System Alarm LED USB3.0 UID Button/LED Rack Handle Product Overview │...
  • Page 12: Chassis Dimensions

    RB13804N4WFT 1-5 Chassis Dimensions Figure 6 Chassis dimensions Figure 7 Label embossing dimensions Product Overview │...
  • Page 13: Available Rack Mounting Kit Options (Refer To "Installation")

    Advisory Note – Available rack and cabinet mounting kits are not designed to support shipment of the server system while installed in a rack. If you choose to do so, Chenbro advises you to verify your shipping configuration with appropriate shock and vibration testing before shipment.
  • Page 14: System Level Environmental Specifications

    RB13804N4WFT 1-7 System Level Environmental Specifications The following table defines the system level specifications under operating and non-operating environments. Table 4 System environmental specifications summary Parameter Specification Temperature Operating 5º C to 35º C (41º F to 95º F) Temperature Non-Operating -40º...
  • Page 15: System Packaging

    1-8 System Packaging The original Chenbro packaging, where the server system is delivered, is designed to provide protection for L6 configuration and tested to meet ISTA (International Safe Transit Association) Test Procedure 1A (2008). The packaging is also designed to be reused for shipment after the system integration has been completed.
  • Page 16: System Components Removal And Installation

    RB13804N4WFT 2. System Components Removal and Installation RB13804N4WFT supports for the following storage: Up to 4 x hot-swap SAS/SATA/NVMe drive in 3.5” bay  Support for different storage and peripheral options will vary depending on the system model and/or available accessory options installed.
  • Page 17: Top Cover Removal And Installation

    RB13804N4WFT 2-1 Top Cover Removal and Installation Figure 8 Rear top cover removal 1. Loosen two screws as shown. 2. Press two buttons together while sliding the rear top cover toward the back of chassis base as the arrow indicating.
  • Page 18: Figure 10 Front Top Cover Installation

    RB13804N4WFT Figure 10 Front top cover installation 1. Align the guide pins of the cover with the grooves on the chassis base, and slide the cover toward the front panel. (two guide pins for both sides) NOTE: Ensure that arrows on the cover indicating the back of the chassis.
  • Page 19: Hot-Swap Hdd Assembly Removal And Installation

    RB13804N4WFT 2-2 Hot-swap HDD Assembly Removal and Installation Figure 12 3.5” hot-swap HDD assembly removal 1. Press the tray button to release the lever as shown. 2. Carefully pull the HDD assembly out of the drive bay. Figure 13 3.5” hot-swap HDD assembly installation 1.
  • Page 20: Figure 14 3.5" Hdd Removal (Tool-Less Type)

    RB13804N4WFT Figure 14 3.5” HDD removal (tool-less type) 1. Loosen a screw as shown and bottom up the HDD tray, and place the HDD tray as shown. 2. Press your two thumbs on the HDD as shown. NOTE: Please operate this on a stable surface in case the HDD dropping unexpectedly.
  • Page 21: Figure 16 3.5" Hdd Removal (Screw Type)

    RB13804N4WFT Figure 16 3.5” HDD removal (screw type) 1. Loosen four screws as shown. 2. Take out the HDD from the tray. Figure 17 3.5” HDD installation (screw type) 1. Align the HDD with the anchor point on the tray.
  • Page 22: Figure 18 2.5" Hdd/Ssd Removal In 3.5" Tray (Screw Type)

    1. Align the front of the HDD/SSD with the anchor point on the tray. 2. Secure the 2.5” HDD/SSD by three screws from the bottom as shown. NOTE: Dedicated screw type is required for 2.5” HDD/SSD Installation, Chenbro P/N: 384-14602-3143A0. System Components Removal and Installation...
  • Page 23: System Maintenance

    RB13804N4WFT 2-3 System Maintenance Figure 20 Removal of whole system from the rack (latch type) 1. Open and hold the latches on both sides as shown. 2. Loosen the screws in the latches and firmly grab the rack handles on both sides.
  • Page 24: Fan Module Removal And Installation

    RB13804N4WFT 2-4 Fan Module Removal and Installation Figure 22 Fan module removal (4056) 1. Detach the mounts on the fan module with the grooves of the chassis base. 2. Loosen four screws as shown to release the fan bracket from the chassis base.
  • Page 25: Figure 24 Fan Module Assembly (4056)

    RB13804N4WFT Figure 24 Fan module assembly (4056) 1. Attach the fan guard with fan as shown and secure it with two screws. 2. Insert four mounts as shown. Figure 25 Fan module installation (4056) 1. Attach the fan bracket with the chassis base as shown and secure it with four screws.
  • Page 26: Figure 26 Air Baffle Removal

    RB13804N4WFT Figure 26 Air baffle removal 1. Remove the air baffle vertically from the fan guard. Figure 27 Air baffle installation 1. Insert the air baffle into the fan guard until it is locked into place. System Components Removal and Installation...
  • Page 27: Pcie Card Installation

    RB13804N4WFT 2-5 PCIe Card Installation Figure 28 PCIe card blank removal Remove the PCIe blank. Figure 29 Cards and brackets installation Secure the riser card with PCIe bracket by two screws. Align two screw holes of PCIe slot bracket with the PCIe card, and secure them with two screws.
  • Page 28: Psu Installation And Removal

    RB13804N4WFT 2-6 PSU Installation and Removal Figure 30 CRPS module installation-1 1. Remove the dummy cover. (Can only support a single CRPS) Figure 31 CRPS module installation-2 1. Insert the CRPS module into the PSU cage until it is secured into place.
  • Page 29: Figure 32 Crps Module Removal

    RB13804N4WFT Figure 32 CRPS module removal 1. Press and hold the latch as shown. 2. Pull the module handle to remove it from the cage. System Components Removal and Installation │...
  • Page 30: Slide Rail Installation

    RB13804N4WFT 2-7 Slide Rail Installation Figure 33 Slide rail installation-1 (84H314610-003) 1. Attach the inner rail to the chassis base while aligning T pins on the side of the system with the slots on the inner rail. Figure 34 Slide rail installation-2 (84H314610-003) 2.
  • Page 31: Figure 35 Slide Rail Installation-3 (84H314610-003)

    RB13804N4WFT Figure 35 Slide rail installation-3 (84H314610-003) 3. Lift the latch as shown. 4. Secure the inner rail with one screw. Figure 36 Slide rail installation-4 (84H314610-003) 5. Install the system into the rack. System Components Removal and Installation │...
  • Page 32: Backplane And Server Board Overview

    RB13804N4WFT 3. Backplane and Server Board Overview Each drive tray includes two LED indicators for drive activity and drive status. Light pipes integrated into the drive tray direct light emitted from LEDs mounted next to each drive connector on the backplane to the drive tray faceplate, making them visible from the front of the system.
  • Page 33: Storage Backplane Option

    RB13804N4WFT 3-1 Storage Backplane Options RB13804N4WFT supports below the backplane: 4-port SAS/SATA/PCIe Gen 3 NVMe (Tri-mode) passive backplane in 3.5” bay  All available SAS/SATA functions include the following common features: 12Gbps SAS and 6Gbps SAS/SATA  SFF-8639 12Gbps rated drive interface connectors, providing both power and I/O signals to attached devices ...
  • Page 34: Figure 38 Backplane Front View

    RB13804N4WFT 3-2 4-Port SAS/SATA/PCIe Gen 3 NVMe (Tri-mode) Passive Backplane Table 8 Backplane specifications Specification Host Interface Mini-SAS HD/OCuLink HDD Interface SFF-8639 Hot-Swap Yes, allows users to replace devices online Display LED indicates storage device status Power LED – Off (Fault) –...
  • Page 35: Figure 39 Backplane Rear View

    RB13804N4WFT Figure 39 Backplane rear view Table 9 Connector and pin header function description Label Connector Description Drawing Power The backplane includes two 1 x 4 connectors supplying power to the backplane. Power is routed to the backplane via a power cable harness from the power supply.
  • Page 36: Server Board Connector Identification

    RB13804N4WFT 3-3 Server Board Connector Identification To Storage Backplane Mini-SAS HD Conn. (SATA) To Storage Backplane OCuLink Conn. (PCIe Gen 3) To Front Panel USB3.0 To Storage Backplane Power Conn. To Storage Backplane Power Conn. To Storage Backplane C Conn.
  • Page 37: Maintenance And Service

    DOA (Dead on Arrival) If the products are found Defect On Arrival, please contact Chenbro’s regional sales or CQE and indicate the defective status via email along with product photos and description. You may need to return the defective item by request.

Table of Contents