Repair; Pressure Relief Procedure; Replace Complete Air Valve - Graco Husky 2200 Repair Parts

Air-operated diaphragm pump
Hide thumbs Also See for Husky 2200:
Table of Contents

Advertisement

Repair

Repair
Repair
Repair
Pressure Relief
Relief Procedure
Procedure
Pressure
Pressure
Relief
Procedure
Follow the Pressure Relief Procedure
whenever you see this symbol.
This equipment stays pressurized until pressure
is relieved manually. To help prevent serious
injury from pressurized fluid, such as splashing
in the eyes or on skin, follow the Pressure Relief
Procedure when you stop pumping and before you
clean, check, or service the equipment.
1. Shut off the air supply to the pump.
2. Open the dispensing valve, if used.
3. Open the fluid drain valve to relieve fluid
pressure. Have a container ready to catch the
drainage.
Replace
Replace
Replace Complete
Complete Air
Complete
Follow these instructions to install Air Valve
Replacement Kit 24V231.
1. Stop the pump. Follow the
Pressure Relief Procedure, page
2. Disconnect the air line to the motor.
3. Remove nuts (104). Remove the air valve (102)
and gasket (105).
10
Air Valve
Air
Valve
Valve
10.
4. Align the new air valve gasket (105*) on the
center housing, then attach the new air valve.
Follow the
Torque Instructions, page
5. Reconnect the air line to the motor.
18.
3A2714H

Advertisement

Table of Contents
loading