Certification
6.2 EMC and Environmental Type Tests
HV Impulse
Damped Os-
cillatory Mag-
netic Field
Environmental Type Tests
60068-2-1
60068-2-2
60068-2-30
60068-21-1
60068-21-2
60068-2-78
60068-2-14
60255-21-2
60255-21-3
Military Standard Tests
36
Description
Signal Ports
DC Power Ports
AC Power Ports
Dielectric
Signal Ports
Strength
DC Power Ports
AC Power Ports
Enclosure Ports
Test
IEC
Cold Temperature
IEC
Dry Heat
IEC
Humidity (Damp
Heat, Cyclic)
IEC
IEC
IEC
Humidity (Damp
Heat, Steady State)
IEC
Change of Temperature
IEC
IEC
Test
MIL-STD-901D
Shock (Hard-Mounted)
MIL-STD-167-1
MIL-STD-461E
Electromagnetic Interference
MIL-STD-1399
MIL-STD-810F
Low Pressure Altitude Storage,
Low Pressure Altitude Opera-
tional, High Temperature Stor-
age, High Temperature Opera-
Description
Test Ad
Test Bd
Test Db
Vibration
Shock
Test Cab
Test Nb
Bump
Seismic
Description
Vibration
Magnetic Field – DC
Magnetic Exposure
Test Levels
5 kV (Fail-Safe Relay Output)
5 kV
5 kV
2 kV
2 kV
2 kV
100 A/m
Test Levels
-40 °C (-40 °F), 16 Hours
85 °C (185 °F), 16 Hours
95% (non-condensing),
55 °C (131 °F), 6 cycles
2g @ 10-150 Hz
30 g @ 11 ms
10 days @ 55 °C (131 °F)
and 93% Relative Humidity
5 Cycles, -40 to 85°
C (40 to 185° F)
10 g @ 16 ms
Method A, Class 2
Test Levels
Grade A, Equipment Class
I, Shock Type A Equipment
Type I (4-33 Hz)
CE101, CE102, CS101, CS114, CS115,
CS116, RE101, RE102, RS101, RS103
Section 070, Part 1
Method 500 Series Procedures
Installation Manual, 01/2020, C79000-G8976-1343-06
Severi-
ty Level
 
 
 
 
 
 
 
Class 1
Class 1
RUGGEDCOM M2200F