Configuring B1/B2/B3 Alarms For Standard Pos Interfaces; Changing The Interface Type - H3C SR6602-X Configuration Manual

Comware 7 interface
Hide thumbs Also See for SR6602-X:
Table of Contents

Advertisement

Step
1.
Enter system view.
2.
Enter POS interface
view or POS channel
interface view.
3.
Enable subinterface
rate statistics
collection for the POS
interface or the POS
channel interface.
4.
(Optional.) Display
collected statistics.
Configuring B1/B2/B3 alarms for standard POS
interfaces
B1, B2, and B3 bytes indicate the signal transmission performance of a line at different levels.
B1 alarm occurs if the bite error rate of a complete STM-N frame exceeds the B1 alarm
threshold.
B2 alarm occurs if the bite error rate of an STM-1 frame exceeds the B2 alarm threshold.
B3 alarm occurs if the bite error rate of a multiplexed signal (VC3 or VC4 frame) in the STM-1
frame exceeds the B3 alarm threshold.
To generate SNMP notifications about these alarms, you must set the alarm thresholds and enable
the notifications.
For more information about SNMP notifications, see Network Management and Monitoring
Configuration Guide.
To configure the B1, B2, or B3 alarm for a standard POS interface:
Step
1.
Enter system view.
2.
Enter standard POS interface
view.
3.
Enable the SNMP notification
about the B1, B2, or B3 alarm.

Changing the interface type

IMPORTANT:
This feature is available only on routers installed with HIM-TS8P interface modules.
You can change the interface type between POS and GigabitEthernet. When you change the
interface type, the system performs the following operations:
Removes the original interface.
Creates a new-type interface with the same number as the original interface.
Command
system-view
interface pos interface-number
sub-interface rate-statistic
display interface pos
Command
system-view
interface pos interface-number
snmp-agent trap enable { b1-tca
| b2-tca | b3-tca }
31
Remarks
N/A
N/A
By default, subinterface rate statistics
collection is disabled.
N/A
Remarks
N/A
N/A
By default, SNMP notifications
about B1, B2, and B3 alarms are
enabled on a standard POS
interface.