Installation; Notes On Safety For The Installation; Handling; Preliminary Checks - Riello RX 500 S/PV Modulating Operation

Premix gas burner
Table of Contents

Advertisement

5

Installation

5.1

Notes on safety for the installation

After carefully cleaning all around the area where the burner is to
be installed, and arranging for the environment to be illuminated
correctly, proceed with the installation operations.
All the installation, maintenance and disassembly
operations must be carried out with the electricity
supply disconnected .
DANGER
5.2

Handling

The packaging of the burner includes a wooden platform, so it is
possible to move the burner (still packaged) with a transpallet
truck or fork lift truck.
The handling operations for the burner can be
highly dangerous if not carried out with the great-
est attention: keep any unauthorised people at a
distance; check the integrity and suitableness of
WARNING
the available means of handling.
Check also that the area in which you are working
is empty and that there is an adequate escape
area (i.e. a free, safe area to which you can quick-
ly move if the burner should fall).
When handling, keep the load at not more than
20-25 cm from the ground.
5.3

Preliminary checks

Checking the consignment
After removing all the packaging, check the integ-
rity of the contents. In the event of doubt, do not
use the burner; contact the supplier.
CAUTION
The packaging elements (wooden cage or card-
board box, nails, clips, plastic bags, etc.) must not
be abandoned as they are potential sources of
danger and pollution; they should be collected and
disposed of in the appropriate places.
Checking the characteristics of the burner
Check the burner identification label (Fig. 10), showing:
 model A) and the type of burner B);
 the year of manufacture, in cryptographic form C);
 the serial number D);
 the electrical supply data E);
 the electrical power consumption F);
 the types of fuel used and the relative supply pressures G);
 the possible minimum and maximum output data of the
burner H) (see Firing rate);
 maximum absorbed current I);
 burner weight L).
20138630
Installation
The installation of the burner must be carried out
by qualified personnel, as indicated in this manual
and in compliance with the standards and regula-
tions of the laws in force.
WARNING
Combustion air inside the boiler must be free from
hazardous mixes (e.g.: chloride, fluoride, halo-
gen); if present, it is highly recommended to carry
DANGER
out cleaning and maintenance more frequently.
After positioning the burner near the installation
point, correctly dispose of all residual packaging,
separating the various types of material.
Before proceeding with the installation operations,
carefully clean all around the area where the burn-
er will be installed.
CAUTION
R.B.L.
D
GAS
II
2R 3R
GAZ
AT BE CH CY CZ DE DK EE ES FI FR GB GR HU
IE IS IT LT LU LV MT NL NO PL PT SE SI SK
20120446
The burner output must be within the boiler's firing
rate;
WARNING
A burner label, or any other component, that has
been tampered with, removed or is missing, pre-
vents the definite identification of the burner and
makes any installation or maintenance work diffi-
WARNING
cult
20
GB
A
B
E
G
H
G
H
RIELLO S.p.A. / I-37045 Legnago(VR)
C
F
I
L
....
Fig. 10

Advertisement

Table of Contents
loading

This manual is also suitable for:

20136698

Table of Contents