NI cRIO-9066 Getting Started Manual page 10

Embedded real-time controller with reconfigurable fpga
Hide thumbs Also See for cRIO-9066:
Table of Contents

Advertisement

6.
Select NI Scan Engine from the software add-ons.
Select any additional software to install. If you plan on using the cRIO-9066 with the
LabVIEW FPGA Module, you can click Next. Click NI Scan Engine if you plan on
using the cRIO-9066 without the LabVIEW FPGA Module.
Tip
7.
Click Next.
8.
Verify that the summary of software to install is correct.
9.
Click Next to start the installation.
10. Click Finish when the installation is complete.
Troubleshooting the cRIO-9066
The cRIO-9066 is Not Communicating with the
Network
Ensure that the USB connections between the cRIO-9066 and the host computer and the
Ethernet connections between the host computer and the router are secure.
Configure the IP and other network settings by completing the following steps.
1.
Use a USB A-to-B cable to connect the cRIO-9066 USB device port to a host
computer. The USB driver creates a virtual network interface card and assigns an IP
address to the cRIO-9066 in the format of 172.22.11.
2.
In MAX, expand your system under Remote Systems.
3.
Select the Network Settings tab to configure the IP and other network settings.
4.
(Optional) Use the RJ-45 Ethernet port 1 to reconnect the cRIO-9066 to the host
computer. The cRIO-9066 attempts to initiate a DHCP network connection at
powerup.
Ensure that you have the correct version of NI-RIO Device Drivers installed on the host
computer. Visit
supported versions of LabVIEW and NI-RIO Device Drivers.
Tip
Device Drivers.
Ensure that the NI USBLAN adapter is recognized in the Device Manager. On
Windows 7, select Start»Control Panel»Device Manager»Network adapters»National
Instruments»USBLAN adapter. If the USBLAN adapter is not recognized, you must
reinstall NI-RIO Device Drivers.
Temporarily disable any network firewalls or other security software.
10 | ni.com | NI cRIO-9066 Getting Started Guide
You can use this wizard at anytime to install additional software.
Note
If the cRIO-9066 cannot obtain an IP address, it connects to the
network with a link-local IP address with the form 169.254.
computer communicates with the cRIO-9066 over a standard Ethernet
connection.
ni.com/info
and enter the Info Code
If you have recently upgraded LabVIEW, you must reinstall NI-RIO
.
x
for the minimum
swsupport
.
. The host
x
x