Work Stage; Modifying The Water Temperature Setting - Ferroli NATURFIRE 30 HR Installation, Use And Maintenance Manual

Pellet heating boiler
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 39
The boiler carries out the startup stages in sequence
according to the procedures defined by the
parameters that manage levels and times, reaching
the work condition unless anomalies or alarms occur,
according to the following table:
After a certain time has elapsed, if the fume temperature has not reached the permissible minimum value the boiler
goes in alarm status.
- Do not use flammable liquids to light the unit.
- In case of persistent failed lighting, contact the Service Centre.

4.4 Work stage

After the 'STARTUP' stage, the boiler goes to the 'WORK' mode which is the normal operation mode.
The user can adjust the heating power from the max. value of 5 to a min. of 1 with the buttons 'P5' and 'P6'.
DHW circuit function activation ON is displayed by the segment/LED [A].
Dialogue box
Power set to
- Make sure to check the pellet level in the hopper so that the flame does not go out due to lack of
pellets.
- Make sure the unit is off when loading pellets.
- The pellet hopper lid must always remain closed; it must only be opened when loading fuel.
- The bags of pellets must be kept at least 1.5 m from the boiler.

4.4.1 Modifying the water temperature setting

To modify the water temperature, press button P1 and then
increase or decrease the temperature parameter with buttons P1
and P2.
When the water temperature has reached the set value, the power
is automatically brought to the min. value, MODULATION status.
When the fume temperature reaches a set max. value the message 'MODULATE F' appears on the control panel and
the stove activates the flame modulation procedure without any user intervention, whereas if the temperature exceeds
285°C the alarm 'AL3 HOT FUMES' appears and the boiler activates the shutdown procedure.
Storage tank or
Puffer H20
Clock
temperature
3
Status
OFF
START - PREHEAT
PELLET PRELOAD
AWAITING FLAME
PELLET LOADING
FIRE PRESENT
WORK
WORK MODULATE
BRAZIER CLEANING
WORK
FINAL CLEANING
A
Button 'P6'
Button 'P5'
Water temperature
Real power in work equal to 1
56
Devices
Fume
igniter
auger
extr.
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
- flashing
Heating chamber water
temperature
NATURFIRE 30-35-39 HR
exch.
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
-