  • Page 1 ® UpER ERvER E200-8D USER’S MANUAL Revision 1.0b...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 About this Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer E200-8D. Installation and maintainance should be performed by experienced technicians only. Please refer to the E200-8D server specifications page on our website for updates on supported memory, processors and operating systems (http://www.supermicro.com).
  • Page 4: Table Of Contents

    SuperServer E200-8D User's Manual Contents Chapter 1 Introduction 1.1 Overview ..........................7 1.2 System Features ........................8 1.3 Chassis Features .........................9 Front Features ........................9 Rear Features ........................10 1.4 Motherboard Layout ......................11 System Block Diagram ......................14 1.5 Server Installation and Setup .....................15 Unpacking the System ......................15 Warnings and Precautions ....................15...
  • Page 5 Contents 3.4 Jumpers ..........................38 Explanation of Jumpers.....................38 3.5 LED Indicators ........................41 3.6 SATA Connections ......................43 Chapter 4 Software 4.1 Driver Installation ........................44 4.2 SuperDoctor 5 ........................45 ® 4.3 IPMI ............................46 Chapter 5 BIOS 5.1 Introduction .........................47 Starting the Setup Utility ....................47 5.2 Main Page ..........................48 5.3 Advanced Page ........................49 5.4 Event Logs .........................70...
  • Page 6 SuperServer E200-8D User's Manual Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 7: Chapter 1 Introduction

    Introduction 1.1 Overview The SuperServer E200-8D is a compact, embedded system comprised of the SC101F chassis and the X10SDV-6C-TLN4F single processor motherboard. Refer to our website for information on operating systems that have been certified for use with the system (www.
  • Page 8: System Features

    SuperServer E200-8D User's Manual 1.2 System Features The following table provides an overview of the main features of the E200-8D. Please refer to Appendix C for additional specifications. System Features Motherboard X10SDV-6C-TLN4F Chassis Compact Embedded Mini ITX Box, SC101F Intel Xeon D-1528 SoC (System on a Chip) in the FCBGA1667 format; CPU TDP support 35W, 9MB cache, 6 Cores, 12 Threads, 1.9-2.2GHz...
  • Page 9: Chassis Features

    Chapter 1: Introduction 1.3 Chassis Features The SC101F is a compact embedded mini-ITX 1U chassis. Front Features The front of the chassis includes the control panel. Figure 1-1. Chassis Front and Control Panel Control Panel Features Item Features Description The main power switch applies or removes primary power from the power supply Power button to the server but maintains standby power.
  • Page 10: Rear Features

    SuperServer E200-8D User's Manual Information LED Status Description Continuously on and An overheat condition has occurred. (This may be caused by cable congestion.) Blinking red (1Hz) Fan failure, check for an inoperative fan. Power failure, check for a non-operational power Blinking red (0.25Hz)
  • Page 11: Motherboard Layout

    Chapter 1: Introduction 1.4 Motherboard Layout Below is a layout of the X10SDV-6C-TLN4F with jumper, connector and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information and jumper settings, refer to Chapter 4. LAN3/4 USB0/1 LED7...
  • Page 12 SuperServer E200-8D User's Manual Jumper Description Default Setting JBR1 BIOS Recovery Pins 1-2 (Normal) JBT1 CMOS Clear Open: Normal, Short: Clear CMOS C1/JI SMB to PCI-Exp. Slots Pins 2-3 (Disabled) JPG1 VGA Enable Pins 1-2 (Enabled) JPL1 LAN1/LAN2 Enable Pins 1-2 (Enabled)
  • Page 13 Chapter 1: Introduction Connector Description LAN1 - LAN2 Gigabit Ethernet (RJ45) Ports) LAN3 - LAN4 10G Ethernet (RJ45) Ports 4-pin 12V DC Power Connector (To provide alternative power for special enclosure when the 24-pin ATX power is not in use.) SLOT7 PCI-E 3.0 X16 Slot SRW1, SRW2...
  • Page 14: System Block Diagram

    SuperServer E200-8D User's Manual System Block Diagram JPCIE1 PCI-E 3.0 PCIE 3.0 x16 PCIE 3.0 x16 M.2 connector PCIE 3.0 x3 PCIE 3.0 x4 PCI-E 3.0 or SATA 3.0 x1 PCIE 3.0 x1 SWITCH PCI-E 3.0 TLN2F and TLN4F only...
  • Page 15: Server Installation And Setup

    Chapter 1: Introduction 1.5 Server Installation and Setup The server is shipped with the onboard processor and the motherboard installed in the chassis. Several steps are necessary to begin using your server. You must add memory, mount the hard disk drive, and mount the system in place. Unpacking the System Inspect the box in which the system was shipped and note if it was damaged.
  • Page 16: Installing Mounting Brackets

    SuperServer E200-8D User's Manual Installing Mounting Brackets Optional brackets allow the server to be mounted in any convenient space in the work environment. 1. Install the brackets, using two screws through the holes in each bracket to secure the bracket to the chassis.
  • Page 17: Installing Rack Mounting Brackets

    Chapter 1: Introduction Installing Rack Mounting Brackets The chassis can be mounted in a rack using two rack brackets and a two-part power adapter shelf bracket (optional, MCP-290-10110-0B). 1. Attach the rack brackets using three screws through the holes in each bracket to secure the bracket to the chassis.
  • Page 18 SuperServer E200-8D User's Manual Notes...
  • Page 19: Chapter 2 Maintenance And Component Installation

    Chapter 2: Maintenance and Component Installation Chapter 2 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components require that power first be removed from the system.
  • Page 20: Accessing The System

    SuperServer E200-8D User's Manual 2.2 Accessing the System The SC101F features a removable top cover to access to the inside of the chassis. Figure 2-1. Removing the Chassis Cover Removing the Top Cover 1. Power down the system as described in section 2.1.
  • Page 21: Motherboard Components

    16GB 16GB 32GB 16GB 16GB 16GB 16GB 64GB 32GB 32GB 64GB 32GB 32GB 32GB 32GB 128GB Check the Supermicro website for a list of memory modules that have been validated. Use memory modules of the same type, speed and frequency.
  • Page 22: Installing Memory

    SuperServer E200-8D User's Manual Installing Memory When installing memory modules, the DIMM slots should be populated in the following order: DIMMA1, DIMMB1, then DIMMA2, DIMMB2. • Always use DDR4 DIMM modules of the same size, type and speed. Mixing memory modules of different types and speeds is not allowed.
  • Page 23: Solid State Storage

    Chapter 2: Maintenance and Component Installation Solid State Storage This motherboard supports an internally mounted solid state storage card by means of an M.2 slot supporting SATA. Figure 2-2. Installing an M.2 Expansion Card Installing the M.2 Card 1. Access the motherboard and locate the M.2 connector (Figure 1.3, JMD1: M2) 2.
  • Page 24: Motherboard Battery

    SuperServer E200-8D User's Manual Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Figure 2-3. Installing the Onboard Battery Replacing the Battery 1.
  • Page 25: Chassis Components

    Chapter 2: Maintenance and Component Installation 2.4 Chassis Components Installing the Storage Drive The SC101F can accommodate a single fixed 2.5" storage drive of 9.5 mm thickness. It is installed to a mounting tray inside the chassis. Use an enterprise quality drive. Figure 2-4.
  • Page 26 SuperServer E200-8D User's Manual 4. Return the drive tray assembly into the chassis, aligning the tabs of the tray with the slots in the chassis. Secure the tray to the chassis support bracket with the screws previously set aside. 5. Attach the cable SATA connector and to the motherboard connector. This cable carries both the SATA signal and the SATA power.
  • Page 27: System Cooling

    Chapter 2: Maintenance and Component Installation System Cooling The SC101F includes two 4 cm fans. One optional additional fans can be purchased. Replacing the System Fan 1. Power down the system as described in section 2.1 and remove the AC power cord and the chassis cover.
  • Page 28 SuperServer E200-8D User's Manual Notes...
  • Page 29: Chapter 3 Motherboard Connections

    Chapter 3 Motherboard Connections Chapter 3 Motherboard Connections This section describes the connections on the X10SDV-6C-TLN4F motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. A motherboard layout indicating component locations may be found in Chapter 1.
  • Page 30: Headers And Connectors

    SuperServer E200-8D User's Manual 3.2 Headers and Connectors Fan Headers This motherboard has three 4-pin fan headers. Although pins 1-3 of the fan headers are backward compatible with the traditional 3-pin fans, we recommend you use 4-pin fans to take advantage of the fan speed control via Pulse Width Modulation through the BMC. This allows the fan speeds to be automatically adjusted based on the motherboard temperature.
  • Page 31 Chapter 3 Motherboard Connections Disk-On-Module Power Connector The Disk-On-Module (DOM) power connector at JSD1 provides 5V power to a solid-state DOM storage device connected to one of the SATA ports. DOM Power Pin Definitions Pin# Definition 1 2 3 DOM Power Pin Layout Ground Ground TPM Header...
  • Page 32 Serial Link General Purpose Headers Pin Definitions Pin# Definition Definition Ground DATA Out Load Ground Clock NVMe I2C Header Connector JNVI2C is a management header for the Supermicro AOC NVMe PCI-E peripheral cards. Connect the I C cable to this connector.
  • Page 33 Chapter 3 Motherboard Connections Power SMBus (I C) Connector Power System Management Bus (I C) Connector (JPI C1) monitors the power supply, fan and system temperatures. Power SMBus Pin Definitions Pin# Definition Clock Data Power Fail Ground +3.3V System Management Bus Header A PCH System Management Bus header for additional replica devices or sensors is located at JSMB1.
  • Page 34: Control Panel

    SuperServer E200-8D User's Manual Control Panel JF1 contains header pins for various control panel connections. See the figure below for the pin locations and definitions of the control panel buttons and LED indicators. All JF1 wires have been bundled into a single cable to simplify this connection. Make sure the red wire plugs into pin 1 as marked on the motherboard.
  • Page 35 Chapter 3 Motherboard Connections Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Power Fail LED Pin Definitions (JF1) Pin# Definition 3.3V PWR Supply Fail Overheat (OH)/Fan Fail Connect an LED cable to pins 7 and 8 of JF1 (Front Control Panel) to use the Overheat/Fan Fail/Power Fail and UID LED connections.
  • Page 36 SuperServer E200-8D User's Manual HDD LED/UID Switch The HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable here to indicate the status of HDD-related activities, including SATA activities. HDD LED Pin Definitions (JF1) Pin# Definition 3.3V Standby/UID Switch...
  • Page 37: Ports

    Chapter 3 Motherboard Connections 3.3 Ports Figure 3-1. Rear Input/Output Ports Rear I/O Ports Description Description IPMI LAN LAN Port 1 USB Port 1 LAN Port 4 USB Port 0 LAN Port 3 LAN Port 2 VGA Port Ethernet Ports Two Gigabit Ethernet ports (LAN1, LAN2), two 10G Ethernet ports (LAN3, LAN4), and an IPMI LAN port are located on the I/O back panel to provide network connections.
  • Page 38: Jumpers

    SuperServer E200-8D User's Manual 3.4 Jumpers Explanation of Jumpers To modify the operation of the motherboard, jumpers are used to choose between optional settings. Jumpers create shorts between two pins to change the function associated with it. Pin 1 is identified with a square solder pad on the printed circuit board. See the motherboard layout page for jumper locations.
  • Page 39 Chapter 3 Motherboard Connections VGA Enable/Disable Jumper JPG1 allows you to enable or disable the VGA port using the onboard graphics controller. The default setting is Enabled. VGA Enable/Disable Jumper Settings Jumper Setting Definition Pins 1-2 Enabled Pins 2-3 Disabled PCI-E Slot SMB Enable (JI C1/JI C1 and JI...
  • Page 40 SuperServer E200-8D User's Manual USB Wake-Up Use the JPUSB1 jumper to enable the function of "System Waking-Up via USB devices" for USB0/1. This jumper allows you to "wake-up" the system by pressing a key on the USB keyboard or by clicking the USB mouse of your system. The JPUSB1 jumper is used together with the USB Wake-Up function in the BIOS.
  • Page 41: Led Indicators

    Chapter 3 Motherboard Connections Gigabit LAN Ports Enable/Disable JPL1 is used to enable or disable the Gigabit Ethernet ports (LAN1~LAN2). GbE LAN Enable Jumper Settings Pin# Definition Enabled (Default) Disabled 10G LAN Ports Enable/Disable JPTG1 is used to enable or disable the 10 Gigabit Ethernet ports (LAN3 ~ LAN4). 10Gb Enable/Disable Jumper Settings Pin#...
  • Page 42 SuperServer E200-8D User's Manual Main Power LED A Main Power LED is located at LED3 on the motherboard. When this LED is on, the system power is on. Be sure to turn off the system power and unplug the power cord before removing or installing components.
  • Page 43: Sata Connections

    There are six SATA 3.0 ports on the motherboard. These ports provide serial-link signal connections with the option of Intel RSTe [RAID 0,1,5,10]. I-SATA0 also supports SuperDOM, Supermicro's proprietary SATA DOM with built-in power connection via pin 8. M.2 Socket M.2 is formerly known as Next Generation Form Factor (NGFF).
  • Page 44: Chapter 4 Software

    This section describes the installation of drivers and management programs for the system. 4.1 Driver Installation The Supermicro FTP site contains drivers and utilities for your system at ftp://ftp.supermicro. com. Some of these must be installed, such as the chipset driver.
  • Page 45: Superdoctor ® 5

    4.2 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 46: Ipmi

    SuperServer E200-8D User's Manual 4.3 IPMI The X10SDV-6C-TLN4F supports the Intelligent Platform Management Interface (IPMI) v2.0. IPMI is used to provide remote access, monitoring and management. There are several BIOS settings that are related to IPMI. For general documentation and information on IPMI, please visit our website at:...
  • Page 47: Chapter 5 Bios

    Chapter 5: BIOS Chapter 5 BIOS 5.1 Introduction This chapter describes the AMI BIOS setup utility for the X10SDV-6C-TLN4F motherboard. It also provides the instructions on how to navigate the AMI BIOS setup utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. Note: Due to periodic changes to the BIOS, some settings may have been added or deleted and might not yet be recorded in this manual.
  • Page 48: Main Page

    SuperServer E200-8D User's Manual 5.2 Main Page When you first enter the AMI BIOS setup utility, you will enter the Main setup screen. You can always return to the Main setup screen by selecting the Main tab on the top of the screen.
  • Page 49: Advanced Page

    Chapter 5: BIOS 5.3 Advanced Page Use this tab page to set some boot, power, CPU, SATA, server ME, and input/output settings. Caution: Take caution when changing the Advanced settings. An incorrect value, a very high DRAM frequency, or an incorrect DRAM timing setting may make the system unstable. When this occurs, revert to the default to the manufacture default settings.
  • Page 50 SuperServer E200-8D User's Manual Bootup NumLock State Use this feature to set the Power-on state for the <Numlock> key. The options are Off and On. Wait For 'F1' If Error Use this feature to force the system to wait until the 'F1' key is pressed if an error occurs.
  • Page 51 Chapter 5: BIOS CPU Configuration The following CPU information will be displayed: • Processor ID • Processor Frequency • Processor Max Ratio • Processor Min Ratio • Microcode Revision • L1 Cache RAM • L2 Cache RAM • L3 Cache Ram •...
  • Page 52 SuperServer E200-8D User's Manual PPIN Control Select Unlock/Enable to use the Protected-Processor Inventory Number (PPIN) in the system. The options are Unlock/Enable and Unlock/Disable. Hardware Prefetcher (Available when supported by the CPU) If set to Enabled, the hardware prefetcher will prefetch streams of data and instructions from the main memory to the L2 cache to improve CPU performance.
  • Page 53 Chapter 5: BIOS If the above is set to Enable, CPU P State will display: CPU P State Control P State Domain This feature allows the user to indicate the P-State domain for each logical process in the system. All processes indicate the same domain in the same package. The options are ALL and ONE.
  • Page 54 SuperServer E200-8D User's Manual Package C State Limit This feature allows the user to set the limit on the C State package register. The options are C0/C1 State, C2 State, C6 (Non Retention) State, C6 (Retention) State, and No Limit.
  • Page 55 Chapter 5: BIOS Workload Configuration This feature allows for optimization of workload. Balanced is recommended. The options are Balanced and I/O Sensitive. Program PowerCTL_MSR PKG C-state Lat. Neg. Use this feature to indicate whether latency should be negotiated with PCH for packaging C-States.
  • Page 56 SuperServer E200-8D User's Manual IIO1 Configuration M.2 PCI-E 3.0 X4 This item configures the link speed of the PCI-E port specified by the user. The options are Gen 1 (Generation 1) (2.5 GT/s), Gen 2 (Generation 2) (5 GT/s) and Gen 3 (Gen- eration 3) (8 GT/s).
  • Page 57 Chapter 5: BIOS Memory Configuration Enforce POR Select Enable to enforce POR restrictions on DDR4 frequency and voltage programming. The options are Enabled and Disabled. Memory Frequency Use this feature to set the maximum memory frequency for onboard memory modules. The options are Auto, 1333, 1400, 1600, 1800, 1867, 2000, 2133, 2200, 2400, 2600, 2667, and Reserved (Do not select Reserved).
  • Page 58 SuperServer E200-8D User's Manual Memory RAS (Reliability_Availability_Serviceability) Configuration Use this submenu to configure the following Memory RAS settings. Patrol Scrub Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor (the original source).
  • Page 59 Chapter 5: BIOS XHCI Hand-Off This is a work-around solution for operating systems that do not support XHCI (Extensible Host Controller Interface) hand-off. The XHCI ownership change should be claimed by the XHCI driver. The settings are Enabled and Disabled. EHCI Hand-Off This item is for the Operating Systems that do not support Enhanced Host Controller Interface (EHCI) hand-off.
  • Page 60 SuperServer E200-8D User's Manual Configure SATA as Select IDE to configure a SATA drive specified by the user as an IDE drive. Select AHCI to configure a SATA drive specified by the user as an AHCI drive. Select RAID to configure a SATA drive specified by the user as a RAID drive.
  • Page 61 Chapter 5: BIOS Port 0 - Port 5 SATA Device Type (Available when a SATA port is detected) Use this item to specify if the connected SATA device is a Solid State drive or a Hard Disk Drive. The options are Hard Disk Drive and Solid State Drive. Server ME (Management Engine) Configuration This feature displays the following system ME configuration settings.
  • Page 62 SuperServer E200-8D User's Manual Maximum Payload Use this feature to select the setting for the PCI Express maximum payload size. The options are Auto, 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes. Relaxed Ordering Select Enable to enable Relaxed Ordering support which will allow certain transactions to violate the strict-ordering rules of PCI bus for a transaction to be completed prior to other transactions that have already been enqueued.
  • Page 63 Chapter 5: BIOS Onboard LAN3 Option ROM Use this option to select the type of device installed in LAN Port 3 used for system boot. The options are Disabled and PXE. Onboard LAN4 Option ROM Use this option to select the type of device installed in LAN Port 4 used for system boot. The options are Disabled and PXE.
  • Page 64 SuperServer E200-8D User's Manual Device Settings This item displays the status of a serial part specified by the user. Change Port 1 Settings This feature specifies the base I/O port address and the Interrupt Request address of a serial port specified by the user. Select Auto to allow the BIOS to automatically assign the base I/O and IRQ address.
  • Page 65 Chapter 5: BIOS Parity A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd.
  • Page 66 SuperServer E200-8D User's Manual SOL Console Redirection Select Enabled to use the SOL port for Console Redirection. The options are Enabled and Disabled. *If the item above set to Enabled, the following items will become available for user's configuration: SOL Console Redirection Settings Use this feature to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user.
  • Page 67 Chapter 5: BIOS Send a "Start" signal to start sending data when the receiving buffer is empty. The options are None and Hardware RTS/CTS. VT-UTF8 Combo Key Support Select Enabled to enable VT-UTF8 Combination Key support for ANSI/VT100 terminals. The options are Enabled and Disabled.
  • Page 68 SuperServer E200-8D User's Manual Out-of-Band Mgmt Port The feature selects a serial port in a client server to be used by the Microsoft Windows Emergency Management Services (EMS) to communicate with a remote host server. The options are COM1 and SOL.
  • Page 69 Chapter 5: BIOS PCI AER Support Use this feature to enable the ACPI OS to manage PCI Advanced Error Reporting. The options are Enabled and Disabled. Trusted Computing (Available when a TPM Device is Detected and TPM Jumper is Enabled) Configuration Security Device Support Select Enable for the AMI BIOS to automatically download the drivers needed to provide...
  • Page 70: Event Logs

    SuperServer E200-8D User's Manual 5.4 Event Logs Use this tab page to manage settings for system event logs. Change SMBIOS Event Log Settings Enabling/Disabling Options SMBIOS Event Log Change this item to enable or disable all features of the SMBIOS Event Logging during system boot.
  • Page 71 Chapter 5: BIOS Memory Corr. Error Threshold Use this item to enter the threshold value for correctable memory errors. The default setting is 10. PCI-Ex Error Enable Select Yes for the BIOS to correct errors occurred in the PCI-E slots. The options are Yes and No.
  • Page 72: Ipmi

    SuperServer E200-8D User's Manual 5.5 IPMI Use this tab page to manage settings for IPMI. BMC Firmware Revision This item indicates the IPMI firmware revision used in your system. IPMI Status (Baseboard Management Controller) This item indicates the status of the IPMI firmware installed in your system.
  • Page 73 Chapter 5: BIOS keep all system event logs after each system reboot. The options are No, Yes, On next reset, and Yes, On every reset. When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full.
  • Page 74 IPMI features. The Disable option is for applications that require faster power on time without using Supermicro Update Manager (SUM) or extended IPMI features. The BMC network configuration in the BIOS setup is also invalid when IPMI Function Support is disabled.
  • Page 75: Security

    Chapter 5: BIOS 5.6 Security Use this tab page to manage security settings. Password Check Select Setup for the system to check for a password at Setup. Select Always for the system to check for a password at bootup or upon entering the BIOS Setup utility. The options are Setup and Always.
  • Page 76 SuperServer E200-8D User's Manual • Secure Boot • Vendor Keys Secure Boot Use this item to enable secure boot. The options are Disabled and Enabled. Secure Boot Mode Use this item to select the secure boot mode. The options are Standard and Custom.
  • Page 77 Chapter 5: BIOS Append Key Select Yes to add the database from the manufacturer's defaults to the existing DB. Select No to load the DB from a file. The options are Yes and No. Forbidden Signatures  Set New Key Select Yes to load the DBX from the manufacturer's defaults.
  • Page 78: Boot Settings

    SuperServer E200-8D User's Manual 5.7 Boot Settings Use this tab page to manage boot settings. Setup Prompt Timeout Use this item to indicate the length of time (the number of seconds) for the BIOS to wait before rebooting the system when the setup activation key is pressed. Enter the value of 65535 (0xFFFF) for the BIOS to wait indefinitely.
  • Page 79 Chapter 5: BIOS • Dual Boot Order #4 • Dual Boot Order #5 • Dual Boot Order #6 • Dual Boot Order #7 • Dual Boot Order #8 • Dual Boot Order #9 • Dual Boot Order #10 • Dual Boot Order #11 •...
  • Page 80: Save & Exit

    SuperServer E200-8D User's Manual 5.8 Save & Exit Use this tab page to manage your exit from the Setup Utility. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration, and reboot the computer. Select Discard Changes and Exit from the Exit menu and press <Enter>.
  • Page 81 Chapter 5: BIOS Discard Changes Select this option and press <Enter> to discard all the changes and return to the AMI BIOS utility Program. Restore Defaults To set this feature, select Restore Defaults from the Save & Exit menu and press <Enter>. These are factory settings designed for maximum system stability, but not for maximum performance.
  • Page 82: Appendix A Bios Error Codes

    When BIOS performs the Power On Self Test, it writes checkpoint codes to I/O port 0080h. If the computer cannot complete the boot process, a diagnostic card can be attached to the computer to read I/O port 0080h (Supermicro p/n AOC-LPC80-20). For information on AMI updates, please refer to http://www.ami.com/products/.
  • Page 83: Appendix B Standardized Warning Statements For Ac Systems

    Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our website at http://www.supermicro.com/about/...
  • Page 84 Appendix B: Standardized Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 85 SuperServer E200-8D User's Manual . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬...
  • Page 86 Appendix B: Standardized Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 87 SuperServer E200-8D User's Manual Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 88 Appendix B: Standardized Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告...
  • Page 89 SuperServer E200-8D User's Manual ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت قبم‬ ‫انىصىل إىن امنناطق انداخهيت نههيكم نتثبيج أو إ ز انت مكىناث الجهاز‬ 경고! 시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원...
  • Page 90 Appendix B: Standardized Warning Statements Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 91 SuperServer E200-8D User's Manual Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial,...
  • Page 92 Appendix B: Standardized Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 93 SuperServer E200-8D User's Manual ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일하거나 제...
  • Page 94 Appendix B: Standardized Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 95 SuperServer E200-8D User's Manual Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 96 Appendix B: Standardized Warning Statements ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 97 SuperServer E200-8D User's Manual ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다.
  • Page 98 Appendix B: Standardized Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 99 SuperServer E200-8D User's Manual Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 100 Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only. 電源コードとACアダプター...
  • Page 101 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 102 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 103: Appendix C System Specifications

    SuperServer E200-8D User's Manual Appendix C System Specifications Processors Single Intel Xeon D-1528 SoC Note: Please refer to the motherboard specifications pages on our website for updates to supported processors. Chipset BIOS 128Mb SPI Flash EEPROM with AMI UEFI BIOS Memory Four DDR4 DIMM sockets;...
  • Page 104 Appendix C: System Specifications Regulatory Compliance Electromagnetic Emissions: FCC Class B, EN 55032 Class B, EN 61000-3-2/3-3, CISPR 32/22 Class B Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN 61000-4-11) Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe) Perchlorate Warning California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products...
  • Page 105: Appendix D Traditional Chinese Version Safety Warnings

    SuperServer E200-8D User's Manual Traditional Chinese Version Safety Warnings Additional Traditional Chinese Version warning statements are included here in this appendix. 安全警告 (注意這些警告標誌) 以下的警告標誌對於安全使用本設備非常重要,可以避免操作人員遭遇危險,以及財產 受到任何損失。 錯誤使用本機器或忽視這本手冊,所引起的傷害或損失等級分類如下: Warning! (警告) 此注意標誌提醒未能依照正確指示使用機器,可能導致生 命危險 或造成嚴重傷害。 Caution ( 注意 此注意標誌提醒未能依照正確指示使用機器,可能導致受傷 或財產損失。 此標誌提示絕對不可做的動作。 此標誌提示一般性務必要採取的行為。 Warnings: (警告) 本機器必須用接地線與地面確實連接。...
  • Page 106 Appendix C: System Specifications Traditional Chinese Version Safety Warnings 1. 勿使用多孔插座或延長線,否則可能造成溫度過高而引起火災。 2. 勿在電源線放置重物,否則可能引起火災或受到電擊。 3. 勿踏在電源線上,及勿損傷或任意處理電源線, 否則可能引起火災或 受到電擊。 4. 勿綁住或紮緊電源線,否則可能引起火災或受到電擊。 5. 勿將花瓶、花盆或盛水容器放在機器上,如果水滴濺出,可能引起火 災或受 到電擊 1. 機器如果產生怪味或不正常聲響,必需立即關閉機器電源開關,然後 從插座 取下插頭 2. 絕對不可以沾濕的手插拔插頭,否則可能受到電擊。 3. 插頭必須確實插妥在插座上,如果未能妥善插好,可能會引起火災。 4. 僅可使用機器所附電源插頭。 拔取電源線時,確實抓住插頭部位,否則導致插頭破裂可能引起火 災或受到電 擊。 不可企圖拆解或擅自修改機器,否則可能引起火災或受到電擊。 不可將機器安裝在下列場所: 1. 濕氣高及多灰塵的地方。 2.
  • Page 107 SuperServer E200-8D User's Manual SuperServer E200-8D User's Manual 警告使用者: 這是乙類的資訊產品,在居住的環境中使用時,可能會造成射頻 干擾,在這種情況下,使用者會被要求採取某些適當的對策 Table 2-1. Declaration of the Presence Condition of the Restricted Substances Marking (限用物質含有情況標示聲明書) 限用物質含有情況標示聲明書 Declaration of the Presence Condition of the Restricted Substances Marking 型號(型式):適用於 E200-8D及其所有系列機種Type designation 設備名稱:伺服器, Equipment name: Server (Type): E200-8D and all its series models 限用物質及其化學符號...