Windsor Saber SX28 Operating Instructions Manual page 14

Walk behind scrubber sx series
Table of Contents

Advertisement

1. SOLUTION CONTROL KNOB
Controls solution flow to scrub deck.
To increase flow, rotate knob clockwise.
To decrease flow, rotate knob
counterclockwise.
If the brush motors are turned off or the
direction control lever is in neutral, the flow is
automatically interrupted until the motors are
turned on again. This feature prevents
unintentional draining of the solution tank and
allows the operator to adjust the solution flow
to the scrub deck without resetting each time
the scrubbing operation is interrupted.
2. ONE TOUCH SWITCH
Controls the scrub brushes and vacuum.
To start scrubbing, press the switch. The
brush drive motors will turn on, the scrub deck
will lower to the "light scrub" position, and the
vacuum motor will turn on. If machine is
equipped with the Auto Squeegee Lift Option,
and the squeegee lift handle is in the lowered
position, the indicator will light to indicate the
scrub brushes are on. This indicator will flash
while the scrub deck is lowering, and
whenever it is adjusting to brush pressure
changes. The Brush Pressure "light scrub"
indicator will light, and the Squeegee/Vacuum
Indicator will light to show the vacuum motor
is on. If the direction control lever is in the
neutral position, the brushes will turn off after
approximately a 2-second delay. If the One
Touch Switch is activated without brushes
installed, the brush motors will stop, the deck
will rise, and the four Brush Pressure Indicator
lights will flash.
To stop scrubbing, press the switch. The
brush drive motors will turn off immediately,
the scrub deck will rise, the squeegee will rise
(if equipped with Auto Squeegee Lift Option),
after approximately a 15 second delay, and
the vacuum motor will turn off after and
additional 15 second delay.
3. VACUUM/SQUEEGEE SWITCH
4. BRUSH PRESSURE INDICATOR/SWITCH
5. BRUSH CIRCUIT BREAKER INDICATOR
6. RECOVERY TANK FULL INDICATOR
SABER 36V (SX) 98739 10/25/99
Controls the vacuum motor, and squeegee
position (if equipped with Auto Squeegee Lift
Option).
To start vacuum motor, press the switch. If
machine is equipped with Auto Squeegee Lift
Option, and the squeegee lift handle is in the
lowered position, the squeegee will lower also.
Controls the amount of brush pressure to the
floor. The indicator shows the setting
selected.
To change brush pressure, press the switch.
Each time the switch is pressed, the brush
pressure will increase until it reaches the
maximum setting. Then the pressure will
return to the minimum setting. If the One
Touch Switch is activated without brushes
installed, the brush motors will stop, the deck
will rise, and the four Brush Pressure Indicator
lights will flash. Under normal conditions, the
brush pressure should be set at the minimum
setting.
Indicator will light when one of the scrub brush
circuit breakers is tripped.
Indicator will light when float switch indicates a
full recovery tank. The indicator will light
intermittently as the tank approaches full.
After the indicator is on continuously for
approximately 70 seconds, the vacuum motor
will turn off, and the squeegee will rise (if
equipped with Auto Squeegee Lift Option).
The vacuum motor will not operate with the
recovery tank full indicator light on.
CONTROLS
3-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Saber sx34Saber sx34sp

Table of Contents