13 - MAINTENANCE AND CLEANING
CLEANING OF SMOKE DUCT AND GENERAL CHECKS:
Clean the smoke extractor duct, especially around the T joints, bends and any horizontal sections. For information on
cleaning the flue, contact a chimney sweep.
Check the integrity of the ceramic fibre seals on the door of the boiler. If necessary, order new replacement seals from the retailer or
contact an authorized service centre to carry out this task.
ATTENTION:
The frequency with which the smoke exhaust system must be cleaned depends on the use of the boiler and the type
of installation.
We recommend relying on an authorized service centre for end-of-season cleaning and maintenance, they will carry
out all of the previously mentioned work and make a general check of the stove's components.
END-OF-SEASON SHUTDOWN
At the end of the season, before shutting down the boiler, we recommend removing all pellets from the hopper with a vacuum cleaner
with an extension.
When starting up the boiler at the beginning of the season, if the control panel display fails to light up when you press the power switch
(located on the back of the boiler), it could mean that the service fuse needs replacing.
There is a fusebox at the back of the boiler underneath the power socket. Open the fusebox cover with a screwdriver and replace the fuse
if necessary (3.15 A delayed) - seek assistance from an authorised and qualified technician.
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel whose technical expertise
includes combustion and electricity.
We recommend that an annual maintenance service is carried out with a scheduled service contract. This service is essentially a visual and
functional inspection of the following components: The following is a summary of the checks and/or maintenance that are indispensable
for the correct operation of the product.
Gearmotor
Smoke extractor fan
Smoke probe
Ignition spark plug
Automatic rearm pellet thermostat
Manual rearm water thermostat
Room/water temperature probe
Motherboard
Fuses protecting panel-motherboard
Wiring
Technical Dept. - All rights reserved - Reproduction is prohibited