Replacing The Fuser Unit - Konica Minolta bizhub 40P Service Manual

Hide thumbs Also See for bizhub 40P:
Table of Contents

Advertisement

3. Periodical check
C. Reinstall procedure
2. Reinstall the toner cartridge.
3. Close the top cover securely.
3.4.9

Replacing the fuser unit

• The temperature gets high in the vicinity of the fuser unit. You may get
burned when you come into contact with the area. Before replacement
operations, make sure that more than 20 minutes have elapsed since the
main and sub power switches were turned off.
A. Periodically replaced parts/cycle
• Fuser unit: Every 200,000 prints
B. Procedure
1. Turn OFF the power switch, unplug the power cord from the power outlet, and let the
machine to stand idle for about 20 min.
[1]
18
1. Pick up the new transfer roller [1] by
[1]
A0DXF2C520DA
CAUTION
2. Lift the lever [1].
A0DXF2C515DA
Field Service Ver. 1.0 Dec. 2007
the levers at both ends, and then slot
it in slowly.

Advertisement

Table of Contents
loading

Table of Contents