C054: Compact Flash Disconnected; C060: Firmware Update Error; C071: Hardware Configuration Error - Konica Minolta bizhub 40P Service Manual

Hide thumbs Also See for bizhub 40P:
Table of Contents

Advertisement

Field Service Ver. 1.0 Dec. 2007
14.3.17

C054: Compact flash disconnected

MFP board (MFPB)
Step
1
Reboot the main body.
Check the compact flash for proper con-
2
nection and correct as necessary.
3
Change compact flash
14.3.18

C060: Firmware update error

MFP board (MFPB)
Step
1
Reboot the main body.
Check the cable that has been used for
2
update of the firmware for proper connec-
tion and correct as necessary.
Check the firmware update file and if the
3
file is not the correct one, update the firm-
ware again.
Check the firmware update procedure and
4
if the procedure is not correct, update the
firmware again.
5
Update the firmware again.
Check the MFPB connector for proper con-
6
nection and correct as necessary.
7
Change MFPB
14.3.19

C071: Hardware configuration error

MFP board (MFPB)
Step
1
Reboot the main body.
Check the MFPB connector for proper con-
2
nection and correct as necessary.
3
Change MFPB
Relevant electrical parts
Action
Relevant electrical parts
Action
Relevant electrical parts
Action
Compact flash card
WIRING DIAGRAM
Control signal
WIRING DIAGRAM
Control signal
WIRING DIAGRAM
Control signal
14. Malfunction code
Location (electri-
cal component)
Location (electri-
cal component)
Location (electri-
cal component)
163