Rugby 820/830, Automatic Field Calibration
Step 3 - Rotate 90° and align to the first side of the Y-axis (Y+)
004742_001
X-axis
Y-axis
X
LED
LED
Off
Flashing
red
Green on Flashing
green
Step 4 - Rotate 180° and align to the opposite side of the Y-axis (Y-)
004743_001
X-axis
Y-axis
X
LED
LED
Off
Flashing
red
Green on Green on
If the calibration process was successful, the X and Y LEDs will flash alternately three
times, the beeper will sound and the Rugby will then turn off.
If the Rugby does not complete the procedure as noted above, the procedure has
failed and must be repeated.
30 m (100 ft)
Y+
Y
X-axis
Y-axis status Actions
status
Off
Y-axis is level-
ling
X-axis is
Y-axis is half
complete
complete
30 m (100 ft)
Y—
Y
X-axis
Y-axis status Actions
status
Off
Y-axis is level-
ling
X-axis is
Y-axis is
complete
complete
Wait until the first side
of the Y-axis is meas-
ured.
Rotate laser 180° until
the X-axis LED is again
flashing red.
Wait until the reverse
of the Y-axis is meas-
ured.
Done.