Leica Rugby 820 User Manual page 39

Hide thumbs Also See for Rugby 820:
Table of Contents

Advertisement

Calibrating
step-by-step
Rugby 820/830, Automatic Field Calibration
The following table defines and displays the LED indications that will be seen during
each step of the field calibration process.
X-axis
Y-axis
LED
LED
Red on
Red on
Step 1 - Rotate and align the first side of the X-axis (X+)
004740_001
X-axis
Y-axis
X
LED
LED
Flashing
Off
red
Flashing
Red on
green
Step 2 - Rotate 180° and align to the opposite side of the X-axis (X-)
004741_001
X-axis
Y-axis
X
LED
LED
Flashing
Off
red
Green on Red on
X
Y
X-axis
status
X-axis not
aligned
30 m (100 ft)
X+
Y
X-axis
status
X-axis is
levelling
X-axis is
half
complete
30 m (100 ft)
X—
Y
X-axis
status
X-axis is
levelling
X-axis is
complete
Y-axis status Actions
Y-axis not
Rotate laser until the
aligned
X-axis LED is flashing
red.
Y-axis status Actions
Off
Wait until the first side
of the X-axis is meas-
ured.
Y-axis not
Rotate laser 180° until
aligned
the X-axis LED is again
flashing red.
Y-axis status Actions
Off
Wait until the reverse
of the X-axis is meas-
ured.
Y-axis not
Rotate laser 90° until
aligned
the Y-axis LED is
flashing red.
39

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rugby 830

Table of Contents