Adjusting the Y-axis
step-by-step
Exiting adjustment
mode step-by-step
Rugby 820/830, Accuracy Adjustment
Step
Description
1.
Press the Up and Down Arrow buttons to increment the laser beam up and
down. Each increment is indicated by a flash of the Y-axis LED and a beep
from the audio indicator.
2.
Continue to press the Up and Down Arrow buttons and monitor the spot
until the Rugby is within its specified range.
Five steps are equal to 10 arc seconds of change, or approximately
1.5 mm at 30 m (1/16" at 100').
3.
Press the Automatic/Manual Mode button to switch back to the X-axis if
desired.
Press and hold the Automatic/Manual Mode button for 3 seconds to save and exit
Adjustment Mode.
The X-axis LED and Y-axis LED flash alternately three times, then the Rugby shuts off.
Pressing the Power button at any time while in Adjustment Mode will exit the mode
without saving changes.