ACU-RITE 01301CCDI Instruction Manual

ACU-RITE 01301CCDI Instruction Manual

Professional weather center

Advertisement

CONTENTS
Unpacking Instructions..................2
Package Contents.........................2
Product Registration......................2
Features: Display Unit...................4
Setup ..........................................6
3-in-1 Sensor Setup......................6
Display Unit Setup........................7
Set Language, Time, Date & Units..8
Questions?
(877) 221-1252 or visit www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Professional Weather Center
model 01301CCDI / 393242
Placement Guidelines .................9
Troubleshooting........................13
Care & Maintenance ................15
Calibration ..............................15
Specifcations...........................16
FCC Information.......................16
Customer Support ....................17
Warranty.................................17
Contact Customer Support at
Instruction Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 01301CCDI and is the answer not in the manual?

Questions and answers

Summary of Contents for ACU-RITE 01301CCDI

  • Page 1: Table Of Contents

    Instruction Manual Professional Weather Center model 01301CCDI / 393242 CONTENTS Placement Guidelines ....9 Unpacking Instructions....2 3-in-1 Sensor Installation ..10 Package Contents......2 Using the Weather Center ..11 Product Registration......2 Troubleshooting......13 Features & Benefts: 3-in-1 ....3 Care & Maintenance ....15 Features: Display Unit....4 Calibration ......15...
  • Page 2: Unpacking Instructions

    Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference. Unpacking Instructions Remove the protective flm that is applied to the LCD screen prior to using this product.
  • Page 3: Features & Benefts: 3-In-1

    Features & Benefits 3-in-1 SENSOR 5. Mounting Hardware Includes anchors and screws. 1. Temperature & Humidity Sensors Diameter Length (internal) 1” 2. Release Lever for Battery Access 3/8” 3. Mounting Point 6. Mounting Bracket 4. Wind Speed Anemometer 7. A-B-C Switch (not shown) ID code that must match display’s A-B-C switch to ensure units...
  • Page 4: Features: Display Unit

    Features & Benefits 3 4 5 6 7 Display Unit...
  • Page 5 DISPLAY UNIT 19. – Button For setup preferences. 1. Current Outdoor Temperature Button Arrow icon indicates direction Press to change the Weather Select temperature is trending. (#23) category being displayed. 2. Sensor Low Battery Indicator 21. Barometric Pressure Arrow icon indicates direction 3.
  • Page 6: Setup

    SETUP 3-IN-1 Sensor Setup Set the A-B-C Switch 1. Press the release lever and pull off the lower housing of the The A-B-C switch is located inside sensor. the battery compartment. It can be 2. Remove the battery compartment set to A, B or C. However, you must cover.
  • Page 7: Display Unit Setup

    Display Unit Setup Set the A-B-C Switch Install or Replace Batteries Locate the A-B-C switch inside the 1. Remove the battery battery compartment. Set the A-B-C compartment cover. switch to A, B or C. You must select 2. Insert 6 x AA alkaline batteries the same letter choices for both the into the battery compartment, display unit and the sensor in order...
  • Page 8 Set the Time, Date & Units Press the “ ” button, located on the front of the display unit, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display. To adjust the currently selected (flashing) item, press and release the “ + “ or “...
  • Page 9: Placement Guidelines

    Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and the sensor are critical to the accuracy and performance of this product. Display Unit Placement Place the display unit in a dry area free of dirt and dust. To ensure accurate temperature measurement, place out of direct sunlight and away from heat sources or vents.
  • Page 10: 3-In-1 Sensor Installation

    3-in-1 Sensor Installation Guidelines INSTALLATION HEIGHT Mount the sensor at least 5 feet (1.5 meters) off the ground (higher is better for wind measurement) in an open area. Secure to fence post, 2”x4” wood, 3/4” pole, etc. (not included) LEVEL INSTALLATION Use a bubble level (not included) to ensure level installation for accurate wind measurement.
  • Page 11: Using The Weather Center

    OPERATION Using The Weather Center Learning Mode Self-Calibrating Forecasting use a unique algorithm to analyze changes in pressure over a time period (called Learning Mode) to determine your altitude. After 14 days, the Learning Mode icon disappears from the display screen. At this point, the self-calibrated pressure is tuned in to your location and the unit is ready for supe- rior weather prediction.
  • Page 12 Weather Select Features weather data groups shown at right. To change “Weather Select” category, press the “ “ button on the front of the display. When outdoor/ indoor temperature or humidity is chosen, the display cycles through the category’s records in this order: 24 Hour Change (data change since 24 hours ago) Today’s HIGH Today’s LOW...
  • Page 13: Troubleshooting

    Troubleshooting Problem Possible Solution • Relocate the display unit and/or the 3-in-1 sensor. The units must be within 330 ft (100 m) of each other. • Make sure both units are placed at least 3 feet (.9 m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc).
  • Page 14 Troubleshooting Problem Possible Solution • Make sure both the display unit and 3-in-1 sensor are placed away from any heat sources or vents (see page 9). • Make sure both units are positioned away from moisture Inaccurate sources (see page 9). temperature or •...
  • Page 15: Care & Maintenance

    Care & Maintenance Display Unit Care Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt and moisture. Clean ventilation ports regularly with a gentle puff of air. 3-in-1 Sensor Care Clean the Sensor Clean with a soft, damp cloth.
  • Page 16: Specifcations

    Specifications Outdoor: -40ºF to 158ºF; -40ºC to 70ºC TEMPERATURE RANGE Indoor: 32ºF to 122ºF; 0ºC to 50ºC Outdoor: 1% to 99% HUMIDITY RANGE Indoor: 1% to 99% 0 to 99 mph; 0 to 159 kph WIND SPEED 330 ft / 100 m depending on home construction materials WIRELESS RANGE 433 mhz OPERATING FREQUENCY...
  • Page 17: Customer Support

    Customer Support AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any of the following ways: (877) 221-1252 info@chaney-inst.com AcuRite 24/7 support at www. .com Installation Videos Register your Product...
  • Page 20 ©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Printed in China 01301CCDI INST 061014 Visit www.AcuRite.com/patents for details.