Crestron TPS-4500V & TPS-4500LV
A control system source file has
the extension .smw. A compiled
SIMPL Windows file has the
extension .spz for a 2-Series
control system, .bin for CNX
generation, and .csz for CNX
generation with SIMPL+.
Operations Guide - DOC. 6160
NOTE: The parameters shown in the previous illustration are the port settings for a
2-Series control system. Consult the Operations Guide for the control system being
used for exact parameter selection.
NOTE: If connecting to the touchpanel through a control system, the baud rate may
need to be set to 38400 baud (Cresnet speed) for a successful transfer.
4. To verify communication, select Diagnostics | Establish Communications
(Find Rack). This should display a window that gives the COM port and
baud rate. If communication cannot be established, refer to the
"Troubleshooting Communications" section in the respective Operations
Guide for the control system.

Uploading a SIMPL Windows Program

The SIMPL Windows file can be uploaded to the control using SIMPL Windows or
via the Crestron Viewport.
Upload via SIMPL Windows
1. Start SIMPL Windows.
2. Select File | Open to view the "Open" window, navigate to the SIMPL
Window file (.smw), and click Open.
3. Select Project | Transfer Program.
Upload via Crestron Viewport
1. Verify that the procedure for "Communication Settings" that begins on page
33 has been performed.
2. As shown after this step, select File Transfer | Send Program
(alternatively, press Alt+P) from the Viewport menu.
File Transfer | Send Program Command
3. The "Send Program" window appears, as shown after this step. Click
Browse, locate the compiled file (.spz) and click Open. This will display
the program's header information and enable one or both of the What to
Send check boxes. If the program does not contain any SIMPL+ modules,
only the SIMPL Program check box will be enabled. If it does contain
SIMPL+ modules, then the SIMPL+Program(s) check box will also be
enabled. Select one or both check boxes and then click Send Program to
begin the transfer.
NOTE: Refer to the respective Operations Guide for the control system for details
about the other fields shown on the "Send Program" window.