1-Way Wireless RF Touchpanels
12 • 1-Way Wireless RF Touchpanels: ST-1550 & ST-1550C
C2Net Device, Slot 9
Double-click the CNRFGWA icon in the upper pane to open the "Device Settings"
window. This window displays CNRFGWA device information. Select the Net ID
tab to change the gateway Net ID, as shown in the following figure.
Device Settings Window for the CNRFGWA
Similarly, expand the system tree in the lower pane and double-click the ST-1550
icon to open the "Device Settings" window for the touchpanel. Select the RF/IR ID
tab to change the touchpanel RF ID, as shown in the following figure. For more
information on setting the RF/IR ID, see Interface on page 5.
NOTE: The hardware and software settings of the RF ID must match. Although the
device setting window in SIMPL Windows allows choices through the range of two-
digit Hexadecimal numbers from 01 through FE, the RF ID setting for the hardware
is limited to numbers in increments of the most significant digit (i.e., 00, 10, 20).
Since 00 is not a valid selection in SIMPL Windows, the RF ID number is limited to
the fifteen numbers 10, 20, 30, 40, . . .F0.