The method for changing the unit's NET ID is identical regardless of the software
chosen. Complete the following steps to change the NET ID.
1. Attach a CNX-BIPAD8 to the control system (verify that the software
is running).
2. From the SIMPL Windows or VT Pro-e menu, select Tools | Viewport
to open the Crestron Viewport.
3. From the Viewport menu, select Diagnostics | Establish
Communications to verify communications.
4. From the Viewport menu, select Functions | Set Network ID. The
software checks the baud rate and then opens the "Set Network ID"
window.
5. In the "Set Network ID" window, select the CNX-BIPAD8 from the
Current Network Devices text window.
6. From the Choose the new network ID for the selected device (Hex): text
box, select the new NET ID for the CNX-BIPAD8.
7. Click Set ID to initiate the change. This will display the "ID command
has been sent" window.
8. In the "Command Complete" window, click OK.
9. In the Current Network Devices text window, verify the new NET ID
code.
10. In the "Set Network ID" window, click Close.
NOTE: The new NET ID code may also be verified by selecting Diagnostic |
Report Network Devices in the Viewport.
11. Repeat this procedure for each CNX-BIPAD8 to be added to the
network.

Rack Mounting

WARNING: To prevent bodily injury when mounting or servicing this unit in a
rack, take special precautions to ensure that the system remains stable. The following
guidelines are provided to ensure user safety.
When mounting this unit in a partially filled rack, load the rack from
the bottom to the top with the heaviest component at the bottom.
If the rack is provided with stabilizing devices, install the stabilizers
before mounting or servicing the units in the rack.
NOTE: If rack mounting is not required, rubber feet are provided for tabletop
placement or stacking. Apply the feet near the corner edges on the underside of the
unit. Refer to "Stacking" for details.
NOTE: Reliable grounding of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections other than direct
connections to the branch circuit (e.g., use of power strips).
Two "ears" are provided with the CNX-BIPAD8 so that the unit can be rack
mounted. These ears must be installed prior to mounting. Complete the procedure
Professional Audio Distribution Processor: CNX-BIPAD8 • 9