5. TECHNICAL CHARACTERISTICS

Characteristics
Operating voltage................................................ 230V
Power consumption............................................. max. 30 mA
Input power.......................................................... 3W on average
External fuse recommended............................... 2A, 250V
Switching power..................................................
(external fuse required)
Surge category....................................................
Input IN4 / IN5.....................................................
GSM-/GPRS module frequency..........................
Required cable ends...........................................
Antenna supplied................................................. MMCX connector, cable length: 3 metres
Operating temperature........................................ -10°C to +55°C
Relative humidity................................................. 90%, not condensed
Weight................................................................. 450 g
Protection class................................................... IP40
Fastening............................................................. Wall-mounted box
Dimensions.......................................................... See above
20
118
118
158
158
Values
250 V
250 V
24 V
Category III, 300 V
OUT1/2/3 and power supply
Low/L logic from 0 to 1.0 V
High/H logic from 1.5 V
GSM900: 880 - 915 MHz
GSM1800: 1710 - 1785 MHz
OUT1/2/3: 2.5 mm²
IN4/5: 1.5 mm²
79
79
50/60 Hz
, 16 A (resistive load)
, 3A (inductive load)
, 16 A
to 32 V