3
4
Benefits
This demo will show the Analog and Discrete Window Teach
functions of the LM Series, as well as RSD recipe control.
• Superior precision for real-world applications
– Resolution 0.004mm
• Best in class Thermal & Mechanical stability
– Temperature Effect +/- 0.008 mm/deg C
• Small housing design for the tightest spaces
– 35.8 mm x 48.5 mm x 23.5 mm
• High response Speed for fast moving targets
– As fast as 0.5 ms
• Simplified set up, control and replacement with optional
Remote Sensor Display(RSD1)
LM Series Demo Kit
5
1
2
Demo Kit (DK-LM150 Series) Components
Models
Description
Precision laser sensor
1
LM150KIQP
Mounting bracket
2
SMBLML1
3
RSD1QP
Remote Sensor Display
4
Sensor Base
Multi-segment target and sensor mount
5
RSD Base
DIN rail mount for RSD
RSD1 Buttons
Use the RSD1 buttons Down, Up, Enter, and Escape to view or
change RSD1 settings and information and to program a connected
sensor.
Down and Up Buttons
Press Down and Up to:
• Access the Quick Menu from Run mode
• Navigate the menu systems
• Change programming settings
• Change individual digit values in distance-based settings
Enter Button
Press Enter to:
• Access the Sensor Menu from Run mode
• Access the submenus
• Move right one digit in distance based settings
• Save changes
Escape Button
Press and hold Escape for 4 seconds to:
• Access the RSD1 Menu while in Run mode
Press Escape to:
• Leave the current menu and return to the parent menu

Advertisement

loading

Summary of Contents for Banner LM Series

  • Page 1 This demo will show the Analog and Discrete Window Teach Use the RSD1 buttons Down, Up, Enter, and Escape to view or functions of the LM Series, as well as RSD recipe control. change RSD1 settings and information and to program a connected sensor.
  • Page 2 Set Up and Demo 1. Connect RSD to LM Sensor 2. Connect RSD to Power 3. Follow Demo Instructions RSD Factory Default Restore 1. Click and hold for >4 sec 2. Click twice to locate the Reset menu 3. Click to enter the Reset menu 4.
  • Page 3 5. Click to teach the 4 mA distance 8. Click to teach the 20 mA distance 6. Position the Target Wheel so the LM150 laser is hitting the 9. Click x 3 to return to Run Mode thickest section 10. Show the mA output change as you rotate the wheel 7.
  • Page 4 Window Teach (Discrete), continued 7. Click to set the window to 0.1 mm 10. Click to perform a mid-point teach moves cursor to the right increase and decrease the number you have selected 11. Click x 3 to return to Run mode 8.