Installation; Preparations; Installing In A Switch Cabinet - Bosch VIP-X16XF-E Installation Manual

Hide thumbs Also See for VIP-X16XF-E:
Table of Contents

Advertisement

VIP X16 XF E
4

Installation

4.1

Preparations

The VIP X16 XF E encoder is designed for installation in a switch cabinet. Mounting the unit in
a 19-inch rack using the installation material supplied is a quick and easy operation.
CAUTION!
The unit is designed for indoor operation.
Select a suitable location for installation that guarantees to meet the environmental
conditions. The ambient temperature must be between 0 and +50 °C (+32 and +122 °F). The
relative humidity must not exceed 95% (non-condensing).
The unit generates heat during operation. During installation, please note the maximum heat
value of 55 BTU/h. Ensure that there is adequate ventilation and enough clearance between
the unit and heat-sensitive objects or equipment.
Please ensure the following installation conditions:
4.2

Installing in a switch cabinet

CAUTION!
When installing in a switch cabinet, ensure that there is sufficient ventilation for the unit.
There must be at least 5 cm (1.97 in) of free space to the left and right of the unit and at least
10 cm (3.94 in) at the rear.
The unit generates heat during operation. During installation, please note the maximum heat
value of 55 BTU/h.
When mounting additional units, direct contact with the encoder is permitted, provided that
the surface temperature of the adjacent units does not exceed +50 °C (+122 °F).
When installing in a switch cabinet, ensure that the screw joints are free of tension and
subject to as little mechanical stress as possible. Ensure that the unit has sufficient
grounding.
1.
2.
3.
4.
Bosch Sicherheitssysteme GmbH
Do not install the unit close to heaters or other heat sources. Avoid locations exposed to
direct sunlight.
Allow sufficient space for running cables.
Ensure that the unit has adequate ventilation. Bear the total heat output in mind,
particularly when installing multiple units in a switch cabinet.
When making connections, use only the cables supplied or use appropriate cables
immune to electromagnetic interference.
Position and run all cables so that they are protected from damage, and provide
adequate cable strain relief where needed.
Avoid impacts, blows and severe vibrations, as these can irreparably damage the unit.
Prepare the switch cabinet in such a manner that you are easily able to insert the unit
directly at the installation point.
Place the cage nuts in the corresponding drillings or spaces in the switch cabinet frame.
Lift the unit into the switch cabinet frame and insert the fastening screws together with
the washers.
Tighten the screws one after the other and then check once more that all the screws are
tight.
Installation Manual