UNIT SIZE 581B
FURNACE SECTION
Rollout Switch Cutout Temp (F)†
Burner Orifice Diameter (in. ...drill size)**
Natural Gas — Std
Liquid Propane — Alt††
Thermostat Heat Anticipator Setting (amps)
208/230/460 v
First Stage
Second Stage
Gas Input (Btuh)
First Stage/Second Stage (3-phase units)
Efficiency (Steady State) (%)
Temperature Rise Range
Manifold Pressure (in. wg)
Natural Gas — Std
Liquid Propane — Alt††
Maximum Static Pressure (in. wg)
Field Gas Connection Size (in.)
HIGH-PRESSURE SWITCH (psig)
Standard Compressor Internal Relief
Cutout
Reset (Auto.)
LOSS-OF-CHARGE SWITCH/LOW-PRESSURE
SWITCH (Liquid LIne) (psig)
Cutout
Reset (Auto.)
FREEZE PROTECTION THERMOSTAT
Opens (F)
Closes (F)
OUTDOOR-AIR INLET SCREENS
Quantity...Size (in.)
RETURN-AIR FILTERS
Quantity...Size (in.)
LEGEND
Bhp —
Brake Horsepower
*Single phase/three phase.
†Indicates automatic reset.
**60,000 and 72,000 Btuh heat input units have 2 burners. 90,000 and
120,000 Btuh heat input units have 3 burners. 115,000 Btuh heat input units
and 150,000 Btuh Heat input units have 3 burners.
††An LP kit is available as an accessory. In order to convert a Low NOx unit to
LP gas, the baffle must be removed. Low NOx units converted to LP gas are
no longer California SCAQMD compliant.
PHYSICAL DATA — 581B036-072 (cont)
036
195
071/072
.113...33
114/115
.113...33
149/150
060N
.102...38
090N
.102...38
120N
071/072
.089...43
114115
.089...43
149/150
.14
.14
072
50,000/ 72,000
115
82,000/115,000
150
071II
—/ 72,000
114II
—/115,000
149II
060N***
—/ 60,000
090N***
—/ 90,000
120N***
072
82
115
80
150
071
82
114
80
149
060N
80
090N
80
120N
072
25-55
115
55-85
150
071
25-55
114
55-85
149
060N
20-50
090N
30-60
120N
3.5
3.5
1.0
1
/
2
||California compliant three-phase models.
***California SCAQMD compliant low NO
84
048
195
.113...33
.113...33
.129...30
.102...38
.102...38
.116...32
.089...43
.089...43
.102...38
.14
.14
50,000/ 72,000
50,000/ 72,000
82,000/115,000
82,000/115,000
120,000/150,000
120,000/150,000
—/ 72,000
—/115,000
—/150,000
—/ 60,000
—/ 90,000
—/120,000
82
81
80
82
81
80
80
80
80
25-55
35-65
50-80
25-55
35-65
50-80
20-50
30-60
40-70
3.5
3.5
1.0
1
/
2
450 ± 50
428
320
7 ± 3
22 ± 5
30 ± 5
45 ± 5
Cleanable
Varies By Option Selected
Throwaway
2...16 x 25 x 2
are controlled to 40 nanograms per joule or less.
060
072
195
195
.113...33
.113...33
.113...33
.113...33
.129...30
.129...30
.102...38
.102...38
.116...32
.089...43
.089...43
.089...43
.089...43
.102...38
.102...38
.14
.14
.14
.14
50,000/ 72,000
82,000/115,000
120,000/150,000
—/ 72,000
—/115,000
—/150,000
—/ 60,000
—/ 90,000
—/120,000
82
82
81
81
80
80
82
81
80
80
80
80
25-55
25-55
35-65
35-65
50-80
50-80
25-55
35-65
50-80
20-50
30-60
40-70
3.5
3.5
3.5
3.5
1.0
1.0
1
/
1
/
2
2