Bryant 581A/B Product Information Manual page 8

Durapac and durapac plus series commercial single package rooftop units gas heating/electric cooling units
Table of Contents

Advertisement

NOMINAL
UNIT 580F
TONS
036
3
048
4
060
5
UNIT
NOMINAL
580F
TONS
072
6
073
6
090
7
1
/
2
091
7
/
1
2
103
8
1
/
2
120
10
121
10
150
12
1
/
2
151
12
1
/
2
LEGEND
dB
— Sound Levels (decibels)
db
— Dry Bulb
EER
— Energy Efficiency Ratio
IPLV — Integrated Part-Load Values
SEER — Seasonal Energy Efficiency Ratio
wb
— Wet Bulb
*Air Conditioning and Refrigeration Institute.
†Applies only to units with capacity of 65,000 Btuh or less.
**The IPLV applies only to two-stage cooling units.
NOTES:
1. Rated in accordance with ARI Standards 210/240 (for sizes 036-
120) or 360, (for size 150 and 151) and 270.
2. ARI ratings are net values, reflecting the effects of circulating fan
heat.
HEATING CAPACITIES AND EFFICIENCIES (Standard-Efficiency Units) — 580F036-151
UNIT
INPUT
580F
CAPACITY
036074
74,000
036115
115,000
048074
74,000
048115
115,000
048150
150,000
060074
74,000
060115
115,000
060150
150,000
UNIT
INPUT
580F
CAPACITY
036060N
60,000
036090N
90,000
048060N
60,000
048090N
90,000
048120N
120,000
060060N
60,000
060090N
90,000
060120N
120,000
ARI* CAPACITY RATINGS — 580F036-151
NET COOLING
STANDARD
CAPACITY
CFM
(Btuh)
1200
35,000
1600
47,000
2000
57,000
NET COOLING
CAPACITY
(Btuh)
72,000
71,000
85,000
88,000
100,000
117,000
114,000
144,000
136,000
208/230-1-60 — SINGLE-STAGE GAS HEAT
OUTPUT
TEMPERATURE
CAPACITY
RISE (°F)
57,000
25-55
89,000
55-85
57,000
25-55
91,000
35-65
118,000
50-80
57,000
25-55
91,000
35-65
118,000
50-80
208/230-1-60 — SINGLE-STAGE GAS HEAT — LOW NOx
OUTPUT
TEMPERATURE
CAPACITY
RISE (°F)
49,000
20-50
73,000
30-60
49,000
20-50
73,000
30-60
98,000
40-70
49,000
20-50
73,000
30-60
98,000
40-70
TOTAL
kW
Belt Drive
4.0
10.0
5.3
10.0
6.7
10.0
TOTAL
EER
kW
8.0
9.0
7.0
10.1
9.6
8.9
8.7
10.1
9.9
10.1
13.0
9.0
11.3
10.1
16.0
9.0
14.3
9.5
3.
Ratings are based on:
Cooling Standard: 80 F db, 67 F wb indoor entering-air tempera-
ture and 95 F db air entering outdoor unit.
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature
and 80 F db outdoor entering-air temperature.
4.
All 580F036, 048, 060, 073, 091, 103, 121, 151 units are in com-
pliance with ASHRAE 90.1-1999 Energy Standard for minimum
SEER and EER requirements. Refer to state and local codes or
visit the following website: http://solstice.crest.org/efficiency/bcap
to determine if compliance with this standard pertains to a given
geographical area of the United States.
5.
All 581B036-120 units are in compliance with Energy Star high
efficiency requirements.
MINIMUM HEATING
AIRFLOW (CFM)
1004
1002
1004
1327
1396
1004
1327
1314
MINIMUM HEATING
AIRFLOW (CFM)
910
1130
910
1130
1300
910
1130
1300
8
SEER†
SOUND
RATING
Direct Drive
(dB)
9.7
81
9.7
81
9.7
81
SOUND
RATING
IPLV
(dB)
81
**
80
**
87
9.40
82
10.5
82
10.4
88
9.40
84
11.0
87
9.20
86
9.70
EFFICIENCY
AFUE (%)
Steady State (%)
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
EFFICIENCY
AFUE (%)
Steady State (%)
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80