581A155 (12 TONS) WITH STANDARD MOTOR (High Heat Units)*
Airflow
0.2
(Cfm)
Rpm
Watts
3750
622
888
4000
652
1015
4250
682
1151
4500
713
1295
4750
744
1448
5000
776
1610
5250
808
1783
5500
840
1967
5750
872
2163
6000
905
2373
6250
937
2596
581A155 (12 TONS) WITH STANDARD MOTOR (High Heat Units)* (cont)
Airflow
1.2
(Cfm)
Rpm
Watts
3750
999
1829
4000
1017
2010
4250
1036
2198
4500
1056
2395
4750
1077
2601
5000
1098
2816
5250
1120
3042
5500
1142
3279
5750
1165
3528
6000
1188
3789
6250
1212
4062
LEGEND
Bhp
Brake Horsepower
Watts
Input Watts to Motor
*Standard low-medium static drive range is 895 to 1147 rpm. Other rpms require a
field-supplied drive.
Refer to page 230 for general Fan Performance Data notes.
581A155 (12 TONS) WITH OPTIONAL MOTOR (High Heat Units)*
Airflow
0.2
(Cfm)
Rpm
Watts
3750
622
888
4000
652
1015
4250
682
1151
4500
713
1295
4750
744
1448
5000
776
1610
5250
808
1783
5500
840
1967
5750
872
2163
6000
905
2373
6250
937
2596
581A155 (12 TONS) WITH OPTIONAL MOTOR (High Heat Units)* (cont)
Airflow
1.2
(Cfm)
Rpm
Watts
3750
999
1829
4000
1017
2010
4250
1036
2198
4500
1056
2395
4750
1077
2601
5000
1098
2816
5250
1120
3042
5500
1142
3279
5750
1165
3528
6000
1188
3789
6250
1212
4062
LEGEND
Bhp
Brake Horsepower
Watts
Input Watts to Motor
*Alternate high-static drive range is 1040 to 1315. Other rpms require a field-
supplied drive.
Refer to page 230 for general Fan Performance Data notes.
PERFORMANCE DATA (cont)
FAN PERFORMANCE — VERTICAL DISCHARGE UNITS (cont)
Available External Static Pressure (in. wg)
0.4
Bhp
Rpm
Watts
Bhp
0.89
713
1027
1.13
1.04
738
1168
1.28
1.20
763
1317
1.45
1.38
790
1474
1.63
1.58
817
1641
1.84
1.80
845
1817
2.06
2.04
874
2003
2.31
2.29
903
2200
2.57
2.57
933
2410
2.86
2.87
963
2634
3.16
3.19
994
2872
3.49
Available External Static Pressure (in. wg)
1.4
Bhp
Rpm
Watts
Bhp
2.15
1059
2091
2.42
2.35
1076
2279
2.63
2.56
1093
2474
2.85
2.78
1112
2675
3.08
3.03
1132
2885
3.34
3.29
1152
3104
3.61
3.56
1173
3332
3.90
3.86
1195
3570
4.20
4.18
1217
3819
4.53
4.51
1239
4080
4.88
4.87
1262
4351
5.24
Available External Static Pressure (in. wg)
0.4
Bhp
Rpm
Watts
Bhp
0.89
713
1027
1.13
1.04
738
1168
1.28
1.20
763
1317
1.45
1.38
790
1474
1.63
1.58
817
1641
1.84
1.80
845
1817
2.06
2.04
874
2003
2.31
2.29
903
2200
2.57
2.57
933
2410
2.86
2.87
963
2634
3.16
3.19
994
2872
3.49
Available External Static Pressure (in. wg)
1.4
Bhp
Rpm
Watts
Bhp
2.15
1059
2091
2.42
2.35
1076
2279
2.63
2.56
1093
2474
2.85
2.78
1112
2675
3.08
3.03
1132
2885
3.34
3.29
1152
3104
3.61
3.56
1173
3332
3.90
3.86
1195
3570
4.20
4.18
1217
3819
4.53
4.51
1239
4080
4.88
4.87
1262
4351
5.24
0.6
Rpm
Watts
Bhp
Rpm
795
1234
1.37
869
818
1388
1.54
890
841
1550
1.72
911
864
1719
1.91
934
889
1896
2.12
956
914
2081
2.35
979
940
2277
2.60
1003
966
2482
2.87
1028
993
2699
3.16
1053
1021
2929
3.47
1078
1049
3172
3.81
1105
1.6
Rpm
Watts
Bhp
Rpm
1117
2343
2.70
1174
1132
2540
2.91
1186
1148
2743
3.14
1201
1166
2951
3.39
1217
1184
3168
3.65
1235
1204
3392
3.93
1253
1224
3626
4.23
1273
1245
3870
4.55
1293
1266
4125
4.88
1313
1288
4389
5.24
NOTES:
1.
Field-supplied motor required.
2. Maximum continuous bhp for the standard motor is 3.13 (for 208/230 and
460-v units) or 3.38 (for 575-v units). The maximum continuous watts is
2700 (for 208/230 and 460-v units) or 3065 (for 575-v units). Do not adjust
motor rpm such that motor maximum bhp and/or watts is exceeded at the
maximum operating cfm. See Evaporator Fan Motor Data tables for more
information.
3. Fan performance is identical for horizontal discharge applications using
Bryant horizontal adapter curb.
0.6
Rpm
Watts
Bhp
Rpm
795
1234
1.37
869
818
1388
1.54
890
841
1550
1.72
911
864
1719
1.91
934
889
1896
2.12
956
914
2081
2.35
979
940
2277
2.60
1003
966
2482
2.87
1028
993
2699
3.16
1053
1021
2929
3.47
1078
1049
3172
3.81
1105
1.6
Rpm
Watts
Bhp
Rpm
1117
2343
2.70
1174
1132
2540
2.91
1186
1148
2743
3.14
1201
1166
2951
3.39
1217
1184
3168
3.65
1235
1204
3392
3.93
1253
1224
3626
4.23
1273
1245
3870
4.55
1293
1266
4125
4.88
1313
1288
4389
5.24
NOTES:
1.
Field-supplied motor required.
2. Maximum continuous bhp for the optional motor is 4.26. The maximum contin-
uous watts is 3610. Do not adjust motor rpm such that motor maximum bhp
and/or watts is exceeded at the maximum operating cfm. See Evaporator Fan
Motor Data tables for more information.
3. Fan performance is identical for horizontal discharge applications using
Bryant horizontal adapter curb.
219
0.8
1.0
Watts
Bhp
Rpm
Watts
1454
1.63
936
1584
1620
1.80
956
1756
1793
1.99
976
1937
1973
2.20
997
2126
2159
2.42
1019
2326
2353
2.66
1041
2536
2556
2.91
1064
2757
2768
3.19
1087
2991
2990
3.49
1110
3237
3225
3.81
1134
3497
3473
4.15
1159
3769
1.8
2.0
Watts
Bhp
Rpm
Watts
2521
2.99
1228
2801
2738
3.21
1239
3023
2962
3.44
1253
3251
3194
3.70
1267
3487
3435
3.97
1284
3731
3683
4.26
1301
3981
3940
4.57
1320
4239
4203
4.89
1339
4501
4471
5.24
0.8
1.0
Watts
Bhp
Rpm
Watts
1454
1.63
936
1584
1620
1.80
956
1756
1793
1.99
976
1937
1973
2.20
997
2126
2159
2.42
1019
2326
2353
2.66
1041
2536
2556
2.91
1064
2757
2768
3.19
1087
2991
2990
3.49
1110
3237
3225
3.81
1134
3497
3473
4.15
1159
3769
1.8
2.0
Watts
Bhp
Rpm
Watts
2521
2.99
1228
2801
2738
3.21
1239
3023
2962
3.44
1253
3251
3194
3.70
1267
3487
3435
3.97
1284
3731
3683
4.26
1301
3981
3940
4.57
1320
4239
4203
4.89
1339
4501
4471
5.24
Bhp
1.89
2.07
2.27
2.49
2.72
2.97
3.24
3.52
3.83
4.15
4.50
Bhp
3.29
3.51
3.75
4.01
4.29
4.59
4.91
5.24
Bhp
1.89
2.07
2.27
2.49
2.72
2.97
3.24
3.52
3.83
4.15
4.50
Bhp
3.29
3.51
3.75
4.01
4.29
4.59
4.91
5.24