Removing The Belt In The Event Of Unit Failure - RADEMACHER RolloTron Comfort DuoFern Translation Of The Original Operating And Assembly Manual

Electronic roller shutter belt winder
Table of Contents

Advertisement

i

20. Removing the belt in the event of unit failure

In the event that the RolloTron Comfort DuoFern unit fails
and the motor no longer runs, you can use the disengaging
bracket provided in order to fully remove the belt from the
belt winder unit, without the need for cutting it.
1.
Remove the mains plug from the socket.
2.
Dismantle the RolloTron Comfort DuoFern as previously
demonstrated on page 75.
There is a risk of injury as the roller shutters may slam
shut or fall in an uncontrolled manner.
◆ Secure the roller shutters from falling.
◆ Hold on to the belt tightly to stop the roller shutters
from slamming shut or falling in an uncontrolled
manner.
◆ Get a second person to help you unlatch the unit.
3.
Release the drive with the help of the supplied disengaging
bracket. A small amount of resistance must be overcome
when pressing.
4.
Maintain pressure on the disengaging bracket and pull the
belt out of the RolloTron as far as possible.
WARNING!
WARNING!
5.
Release the belt from the fastening hook and pull it out
completely from the RolloTron.
6.
Replace the disengaging bracket in its holder.
RolloTron
Comfort
Drive release
DuoFern
RolloTron
Comfort
DuoFern
Plus
Drive release
EN