Technical Data

The figures have been determined according to DIN 12876.
Calibration thermostat
Working temperature range
Ambient temperature range
Setpoint resolution
Display resolution
Display
Temperature stability
Safety feature 
Miscellaneous functions
Heating capacity
230 V; 50 Hz
230 V; 60 Hz
115 V; 60 Hz
Eff. Cooling capacity @
with Ethanol
at ambient temperature
20 °C
Pump type
Pump output max.
Discharge pressure max. 
Pump connections (for tubing)
Bath filling capacity max.
Bath opening (B x T)
Bath depth
Working depth
Height upper surface of bath
Overall dimensions (B x T x H)
Weight
Power consumption
230 V; 50 Hz
230 V; 60 Hz
115 V; 60 Hz
 FL
compatible for flammable and non-flammable liquids.
at pumping capacity stage
 
not valid when used for calibrating, because the pressure connection is used for a connecting tube
27.06.2018/YACE0068
°C
°C
°C
°C
K
kW
kW
kW
20 °C
kW
0 °C
kW
-20 °C
kW
-30 °C
kW
bar
L/min
mm
L
mm
mm
mm
mm
mm
kg
kW
kW
kW
5
Technical Data
RE 212 J
- 30 – 200
0.1 / 0.01
0.05
±0.2 K with additive calibration
2-line LCD-display
Automatic compressor, Cooling capacity adjustment
2.25
2.25
1.3
0.30
0.23
0.13
0.04
Pressure pump with selection of 5 power stages
Nipples dia 13 mm (M16 x 1)
250 x 400 x 602
2.3
2.3
1.4
RE 312 J
5 – 40
0.1 / 0.05 / 0.01
±0.01
FL
2-line LCD-display, program
compilation, external control,
analog inputs/outputs
2.25
2.25
1.3
0,30
0,23
0,13
0,04
0.4 
17 
9 – 12
Ø 150
200
180
441
30
2.3
2.3
1.4