Temporarily Remove Cec Drawer <= Ssr Task - IBM Power 775 Manual

Cec drawer rails service procedure
Hide thumbs Also See for Power 775:
Table of Contents

Advertisement

3.7
Temporarily remove CEC Drawer <= SSR TASK
DANGER:
Rack-mounted devices are not to be used as shelves or work spaces. (L002)
CAUTION:
System or part is heavy. The label is accompanied by a specific weight range. (L009)
CAUTION: Do not remove or install this unit without using the provided lift tool. (C017)
STEP 41
As necessary, place the ladder on the right side of the Lift Tool to allow access to CEC Drawer
Safety Latch.
STEP 42
Slide the CEC Drawer out until the safety stop is reached. Note that the CEC drawer should
slide ~2/3 of the way out and then stop on the right side Safety Latch.
STEP 43
Raise the Lift Tool Table so it contacts the bottom of the CEC Drawer and then slightly further
to transfer the CEC Drawer weight to the Lift Tool Table. Important, do not raise too high which will result in
the CEC Drawer being driven into the mechanical device above. This can cause damage.
STEP 44
After the CEC Drawer stops on the Safety Latch, carefully slide the CEC Drawer back ¼-½
inch into the Rack.
STEP 45
On the right-hand side, insert the 4mm Hex Driver (41V1059) into the gap between CEC
Drawer and Rack so that the 4mm Hex Driver rests on the bottom side of the Safety Latch Lift Pin. See Figure
30.
Power775 CEC Drawer Rails Service Procedure
PN: 41U8495, EC N44172
Page 32 of 42