Identify The Frame <= Ssr Task - IBM Power 775 Manual

Disk enclosure fan service procedure
Hide thumbs Also See for Power 775:
Table of Contents

Advertisement

3.3 Identify the frame <= SSR TASK
STEP 4
Use the procedure "Appendix A: Power775 BPC FSP Command Line Procedure" (included in Section 5 of this
document) to access the BPC FSP command line of the frame containing the Disk Enclosure with the FRU
needing replacement.
STEP 5
Blink the Enclosure Identify LEDs of the DE with the FRU needing replacement by using the following command
from the BPC Command Line:
This is the command syntax:
bpccmd –c 27<blank>0000<cage ID><FRU ID><LED blink state 00=off, 02=blink>
Type in the following, inserting the correct Cage ID DE chassis location:
bpccmd –c 27110000xx0102
The correct return code is 001100. If you do not receive this, contact the next level of support.
Below is an example assuming Cage ID=0f
Power775 Disk Enclosure Fan Service Procedure
.
<blank>
= "11"
<cage ID>
= see Figure 6
<FRU ID>
= "01" for the DE Identify LED.
<LED state>
= "02" for this step
Where "xx" is the Cage ID of the DE you are servicing. This field will be 05,07,09,0B,0D, or
0F (see Figure 6).
16 of 61

Advertisement

Table of Contents
loading

Table of Contents