Congratulations on selecting a Dayliff DP Solar Pool Pump. They are manufactured to the highest standards and if installed and operated correctly will give many years of efcient and trouble free service. Careful reading of this Installation Manual is therefore important, though should there be any queries they should be referred to the equipment supplier.
Page 4
MOTOR The pump is connected to a maintenance free, brushless DC motor. The motor runs on variable speed to 3000rpm providing excellent performance and efficiency. Enclosure Class: IPX4 Insulation Class: F PUMP OUTPUTS Pump output curves are given at standard test conditions of 1000W/m solar irradiance and 25 C .Output will vary throughout the year depending upon prevailing irradiation levels.
Value Parameters Alarm 57.6+0.4VDC Over Charge Recover 14.4+0.4VDC Switch Off 44.0+0.4VDC Over Discharge Recover 47.2+0.4VDC Overload 15+0.4VDC Current Overcurrent 29.4+0.4VDC Protection Function Protection Program Description "B+""B-" connected with contrary poles of batteries, the controller still work when coeected ; "PV+""PV-" connected with contrary poles of PV Reverse Protection panels, the controller still work when coeected.
Do not touch or inspect the components or signal of the printed circuit board. WARNING Do not touch the radiator or fever parts, to prevent scalding. WARNING 3. INSTALLATION 3.1 Wiring Diagram As shown below. Turn the switch to "BATTERY". 3.2 Technical Program...
Terminal Description Connect with the anode of solar array Connect with the cathode of solar array Connect with the anode of battery (for 48V pumps only) Connect with the cathode of battery (for 48V pumps only) Connect with the motor wire (brown) Connect with the motor wire (green) Connect with the motor wire (black) 4.
Page 8
4.2 Board Description SYMBOL SYMBOL DESIGNATION DESCRIPTION 1. Enter setting menu SET / DOWN DOWN 2. Choose function 1. Parameters display VAP / UP 2. Choose parameter 1. Parameters display PLUS 2. Choose parameter 1. Stop manually MINUS 2. Adjust 1.
Page 9
4.4 Introduction of Parameters Default Display SRMIV 100%15 V: 20-85V 0:03 S: Power Active R: Pump Active M: MPPT Active I: Overcurrent Protection Active V: Overvoltage Protection Active 100%: Motor Speed 100% 15: Protection Reset Interval 15 minutes V: 20-85V : The range of input voltage 199 : Startup times 0:03:20 Run Duration (H/M/S) Default display on running state;...
Page 10
SV: Voltage of PV Panels I: Working Current BV: Voltage of Batteries C: Charging Current T: Run Duration P: Power N: Motor Speed 30: Time (S) Under default setting, press"VAP/UP"button, LCD shows the voltage, current, power. After 40seconds, back to default.
5. TERMS OF WARRANTY i) General Liability • In lieu of any warranty, condition or liability implied by law, the liability of Dayliff (hereafter called the Distributor) in respect of any defect or failure of equipment supplied is limited to making good by replacement or repair (at the Distributor’s discretion) defects which under proper use appear therein...