Altronix AL6003X220 triple output access control power supply/charger is specifically designed for use with access
control systems and accessories. The AL6003X220 converts a 220VAC 50/60Hz input into three individually PTC
protected 5VDC, 12VDC and 24VDC regulated outputs (see specifications).
Input:
• Input 220VAC (working range 198VAC - 256VAC),
50/60Hz, 1.25A.
Output:
• 1.75A continuous supply current @ 5VDC.
• 1.75A continuous supply current @ 12VDC.
• 3A continuous supply current @ 24VDC.
• Filtered and electronically regulated outputs,
100mV peak output voltage ripple.
Battery Backup:
• Built-in charger for sealed lead acid or
gel type batteries.
• Automatic switch over to stand-by battery
when AC fails.
• Maximum charge current 0.7A.
Output
24VDC / 12AH Battery
24VDC / 40AH Battery
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with
all local codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes
in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place
the enclosure's upper keyholes over the two upper screws, level and secure. Mark the position of the lower
two holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure's
upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws
(Enclosure Dimensions, pg. 4). Secure enclosure to earth ground.
It is recommended to first review the following tables for screw terminals, switch selection and LED status
indications. This will greatly facilitate installation hook-up.
Carefully review:
Stand-by Specifications
LED Diagnostics
Terminal Identification Table
2. Connect AC circuit (220VAC, 50/60Hz) as follows: Green branch wire connects to earth (safety) ground
lug. Line and Neutral to the connector on power supply board marked [L, N] respectively (Fig. 1, pg. 3).
Use 14 AWG or larger for all power connections (Battery, DC output, AC input).
Use 22 AWG to 18 AWG for power-limited circuits (AC Fail/Low Battery reporting).
Keep power-limited wiring separate from non power-limited wiring (220VAC 50/60Hz Input,
Battery Wires). Minimum 0.25" spacing must be provided.
CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing
equipment. There are no user serviceable parts inside. Refer installation and servicing to qualified
service personnel.
AL6003X220
Triple Output Access Control Power Supply/Charger
Overview:
Specifications:
Stand-by Specifications
(current is specified on AL3XB input):
4 hr. of Stand-by and
5 Minutes of Alarm
–
Stand-by = 6.0A
Alarm = 6.0A
Installation Instructions:
(pg. 1)
(pg. 2)
(pg. 2)
Battery Backup (cont'd):
• Zero voltage drop when switched over to
battery backup.
Supervision:
• AC fail supervision (form "C" contacts).
• Low battery supervision (form "C" contacts).
Additional Features:
• Thermal and short circuit protection with auto reset.
• Power supply is complete with enclosure,
cam lock, and battery leads.
Enclosure Dimensions (H x W x D approximate):
15.5" x 12" x 4.5"
(393.7mm x 304.8mm x 114.3mm)
24 hr. of Stand-by and
5 Minutes of Alarm
Stand-by = 200mA
Alarm = 6.0A
Stand-by = 1.0A
Alarm = 6.0A
60 hr. of Stand-by and
5 Minutes of Alarm
–
Stand-by = 300mA
Alarm = 6.0A