A. Connect / Disconnect
Open the "Viking IP Programming" software on the PC and the start screen shown below will appear. Any Viking IP
phones that are connected to the network will appear on the list. Simply select the Entry Phone on the list and click on
the "Connect" button at the bottom or double click the selected phone. If the security code of the selected phone is still
set to default (845464), the PC software will not require entering a security code to connect to the phone. Entry Phone's
have a default name of "VIKING_MK64_Vik02", so if many phones are connected to the same network that all have
the default name, MAC addresses must be used to identify each phone.
When finished programming, click on the "Disconnect" button at the bottom. Closing the program will also automatically
disconnect the unit.
B. Manually Muting SIP / Network Failure Alarm Beeps
With the unit connected and powered (Green LED on and Yellow LED off or blinking) it will output 3 beeps every 30
seconds and turn the Call/Call Connected LED (E-30-IP / E-32-IP only) on and off once per second indicating a SIP
registration failure, failure to receive an echo reply from pinged gateway or Ethernet connection failure. You can manually
disable the beeps by pressing and holding the Call button for 5 seconds (2 beeps will then be heard) or by clicking the
"Mute Alarm Until Next Failure" tab in the Viking VoIP programming software. The LED will continue to flash allowing
you to trouble shoot the failure.
(3 beeps repeated every 30 seconds)