Viking E-10-IP Product Manual page 12

Voip entry phones
Hide thumbs Also See for E-10-IP:
Table of Contents

Advertisement

DESCRIPTION
Connect/Disconnect
VLAN Settings
Unit Name
SIP Server
Peer to Peer Settings
Outbound Proxy
Authentication ID
Register Fails
Speed Dial Numbers
Security code (factory set to 845464)
ID Number
Access Code (1 - 6 digits, blank = disabled, factory set to 123456)
Internal / External Relay (factory set to Internal)
Relay Mode (Door Strike, Outbound Call, In / Outbound Call, Doorbell, LV-1K Control, Ring, Ring Flash, factory set to Door Strike)
Relay Activation Command (1 or 2 digits, factory set to
Relay Activation Time (0.5 - 99 sec, factory set to 5 seconds)
Relay Buzz Volume (1 - 3 or Disabled, factory set to 3)
Relay Latch Commands (Enabled or Disabled, factory set to Enabled) NOTE: Relay Mode must be set to Door Strike
Alternating Switch Action
Speaker Mode (ON, OFF / Silent Monitor or OFF until Answered, factory set to ON)
Speaker Volume (0 - 9, factory set to 3)
Ring Volume (0 - 9, factory set to 5)
Microphone Volume (0 - 9, 0 = Auto, factory set to 5)
Talk/Listen Delay (VOX) (0.1 - 0.9 seconds, factory set to 0.5 seconds)
In-Band Audio Call Progress (Enabled, Disabled, factory set to Enabled)
In-Band Audio Detect Sensitivity (1 - 9, 1 = minimum, 9 = maximum, factory set to 5, power cycle unit after setting)
Lap Counter (1 - 9 or Disabled, factory set to Disabled)
Call Length Time Out (disabled or 1 - 9 minutes, factory set to 3 minutes)
Inbound Call Mode (Disabled, Auto Answer, Auto Answer-Secure, Ring, Ring with AGC, factory set to Auto Answer)
Ring Cadence (factorty set to Normal, 2 seconds on 4 seconds off)
Dial Next Number on RNA (Ring No Answer) (disabled, 1 - 9 = number of rings, factory set to 7)
Dial Next Number on Busy (disabled or enabled, factory set to Enabled)
Send ID Numbers as (RFC 2833 or In Band DTMF, factory set to RFC 2833)
Call LED Mode (OFF, Entry Phone, Emergency Phone or Emergency Outbound only, factory set to Entry Phone)
Call LED Control (Automatic or enter
Mute Current / Next Alarm
Permanent Alarm Mute (factory set to Alarm Tones Enabled)
IP Firmware
Unit Firmware
Import/Export
Clear Unit Settings
Clear IP Settings
Diagnostics (used to check mic, speaker and relay operations)
REX Input
Programming Features Index
QQ
) NOTE: Relay Mode must be set to Door Strike
to light, factory set to Automatic)
Q
12
Section
Page
A
9
D
11
1
13
2
13
3
13
4
13
5
13
6
13
7
14
8
14
9
14
10
14
11
15
12
15
13
16
14
16
15
16
16
16
17
16
18
16
19
16
20
16
21
17
22
17
23
17
24
17
25
17
26
17
27
18
28
18
29
18
30
18
31
18
32
19
33
19
34
19
35
20
36
20
37
20
38
20
39
20
40
20
41
20
42
20

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents