Procedure 31
Hood Access - disconnect power
to hood.
Step 1: Pull stove away from wall
Step 2: Remove filters (using the
plastic tabs at the front of the filters,
push the filters backwards and at
the same time pull down on the
tabs).
Step 3: Remove three front colored
screws on access panel and three
vertical screws on top edge above
access panel.
Step 4: Once screws are removed,
pull on control panel at an angle to
allow panel to clear sides of hood.
This will expose all the electrical
connections and blowers.
- Closet Exhaust Fan
Blower Removal - disconnect
power to hood.
Step 5: Remove molex pins from
hoods to disconnect wires.
Step 6: Blowers are held in place
by two screws fastening the blower
to the top of the hood and by small
tabs.
Step 7: Once screws are removed,
pull blower to the left to free tabs
and out
Step 8: Blowers are held in place
by two screws fastening the blower
to the top of the hood and by small
tabs.
Step 9: Once screws are removed,
pull blower to the left to free tabs
and out
49
Section 5-3
Hood Removal - disconnect power
to hood.
Step 10: Disconnect wires to
terminal block (hoods are all hard
wired as they are not supplied with
a wall plug)
Step 11: Hoods are held in place to
the wall by two or four screws
fastened directly to a support wood
strip or a wood plate (depending on
installation). Please refer to Hood
Installation Manual for additional
details.
6
6
7
Back Insta llation
Strip Installation
Step 12: Top of Hood should be
connected and sealed to rigid
galvanized ducting by an adaptor
(supplied with the hood). Duct tape
may need to be cut to allow the
hood to be free from the outside
ducting.
6 0 0 o r 9 0 0 C F M
8 " d u c t tra n s itio n
O p tio n a l
d u c t c o v e r
11-1/2 "
21 "
MLSM2003-01-03
Top (canopy) Installa tion
8"
3 1/2 "

Advertisement