Procedure 7
Step 1: Disconnect power supply
to range.
Step 2: Pull range away from wall.
Step 3: Remove range's back
panel & convection fan baffle. See
Procedures 32 and 6 (steps 5-8)
respectively,
Step 4: Bake/Broil limit is located
near the upper right corner inside
the oven cavity, next to the oven
thermostat probe.
Step 5: From back of the stove,
check for visible damage to the
limit's body and wire connections.
- Bake/Broil Limit
Step 6: Test bake/broil limit for
continuity across terminals.
Step 7: Pull both sets of wires,
place probes on terminals. If no
continuity, replace limit.
Step 8: If limit tests in good order.
Test wiring from elements to limit
and from relay board to limit for
signs of damage and continuity.
Also check wires to safety limit
(Procedure 8) and to self clean
microswitch selector (Procedure
17).
Step 9: To replace bake/broil limit,
open oven door and remove for
easier access (See Procedure 33)
Step 10: Place masking tape over
nut head protruding inside the oven
to hold in place.
Step 11: From back of range,
remove nut(s) holding bake/broil
limit and transfer wires to new limit
in the exact same locations.
23
Section 5-3
Caution: Use extreme care when
handling self clean oven thermostat
probe and wire. Do not bend
excessively or repeatedly. Contents
of probe (sodium and potassium
hydroxide) produce lye in the
presence of moisture. If contents
contact skin, remove with dry towel
or cloth (NEVER USE WATER).
Then wash area thoroughly with
water and soap. If assembly
ruptures, crimp broken ends with
pliers.
MLSM2003-01-03